User Guide
Targets.....107
To view and control the SP's indicator LED:
1. Click an SP name.
2. Click the System tab. The system information window appears and the current chassis LED
status of the target device is displayed under the Enclosure heading.
3. To change the indicator status of the target device, complete any of the following steps:
To turn the LED on and leave the LED flashing for a specified number of seconds, check the
button next to Indicator Blink then enter the number of seconds in the Seconds field.
- or -
To turn the LED on and leave the LED flashing, check the button next to Indicator On.
- or -
To turn the LED off, check the button next to Indicator Off.
4. Click Apply. The Indicator Status will reflect your changes.
To view and control the time setting:
1. Click an SP name.
2. Click the System tab.
3. Select either synchronize with appliance or synchronize with client PC and click Apply.
SEL
The SEL tab displays all of the System Event Log (SEL) entries returned from the service
processor. An administrator can filter all entries in the table by inputting a case sensitive text string
and clicking Filter. Click Clear All to remove all SELinformation and click Refresh to refresh the
page.
Sessions
From the Sessions tab, you can open sessions with an SPon the appliance as well as view a list of
all sessions by all users to a target SP. The Sessions page contains buttons based on the abilities
of the SP and the permissions of the user viewing the page.
SP Access sessions allow direct browser/vKVM connection from a remote client to SPs being
managed by the appliance.
SP Access is supported for SPs that are both physically connected to the appliance and SPs that
are logically managed by IP and not physically connected to the appliance.
The framework used to provide SP Access is built upon the basic principle of a reverse proxy and
replaces the DirectCommand architecture.