User's Manual

b. Type the port number for the hub server.
If the default hub server port value (443) is modified, you must specify it
when registering a spoke server so that register requests will be sent to the
correct port on the hub server. For example, if the IP address of the hub server
is 10.0.0.1 and the port number is changed to 444, type
https://10.0.0.1:444/RPM in the Address field of the Register Spoke Server
Wizard.
c. Click Next.
6. The Operation in Progress window will open briefly, followed by the Accept Hub RPM
Server Certificate window. Click Next.
7. The Type in Hub RPM Server Administrator Credentials window will open. Click Next.
8. Type the name of a user with Rack Power Manager software administrator privileges on the
hub server. Type a password for the user. Click Next.
9. The Operation In Progress window will open. The configuration of the spoke server will be
saved to the database of the hub server and the spoke server’s certificates will be installed
on the hub server.
10. The Completed Successful window will open when the spoke server has been added.
11. Click Finish.
To change spoke server network properties:
NOTE: Spoke server network settings may need to be changed by Rack Power Manager software administrators
when network settings are changed and the hub server did not automatically detect the changes. When changing
the network settings, ensure that a port mismatch does not occur between the hub server and the spoke server.
1. On the hub server, click the System tab.
2. Click RPM Server in the top navigation bar. The side navigation bar will include the name
of the server to which you are logged in.
3. Click Properties in the side navigation bar, and then click Spoke Servers. The Spoke
Servers window will open.
4. Click on the name of the spoke server whose network properties you wish to change. The
Spoke Server Network Properties window will open.
5. Change any of the following network settings:
Type a new computer name to use as the spoke server.
Type a new address in standard dot notation (xxx.xxx.xxx.xxx) for the spoke server.
76Rack Power Manager Installer/User Guide