target name will be reset to the configured target name or to the corresponding unique default
target name.
NOTE: The configured target name will be used only after the auto discovery process fails.
NOTE: The auto discovery process starts when there is variation in the DCD signal from OFF to ON
(disconnect/connect the target's cable, turn off/on the target) and when the configuration of the serial port
goes from disabled to enabled and there is a target connected in the port.
The probe strings will be used to stimulate the server (such as \n”: a single newline).
The match strings are regular expressions where %H is a placeholder for the target name you
want to detect, such as:
“\\(.*\\)(%H)\\(.*\\)” or just “xxx%Hyyy”.
The first one will extract target name from things such as:
nanana(myTarget): à results: myTarget
jhdsgjhas(tg2)kjafja à results: tg2
And the second one from things such as:
hsagdfjhagfxxxTARGETyyyyyy à resulting: TARGET
To configure the strings for probe/match used by auto discovery:
Perform this procedure to change the default settings or the probe or match strings used in auto
discovery.
1. Select Ports - CAS Profile - Auto Discovery. The Settings, Probe Strings and Match Strings
options appear in the side navigation bar.
2. To change the default auto discovery time-out or probe time-out, perform the following steps.
a. Select Settings.
b. Enter a new value in the Auto Discovery Timeout and Probe Timeout fields.
c. Select a speed from the Default Speed on Auto Discovery Failure drop-down menu and
Probe Speed List.
d. Click Save.
3. To add a new probe or match string or delete an existing string, perform the following steps.
a. Select Probe Strings or Match Strings.