User Guide

Accessing the Console Server via the Web Manager.....41
Parameter Description
Speed
Defines the speed as 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600 or
115200. Default: 9600.
Parity Defines the parity as either Even, Odd or None. Default: None.
Data Bits
Defines the data bits as either 5, 6, 7 or 8. Default: 8.
Stop Bits Defines the stop bits as either 1 or 2. Default: 1.
Flow Control
Defines the flow control as none, hardware, software, RxON software or TxON
sofware. Default: None.
Power
PDU Type
Defines the type or vendor of the PDU connected to the serial port.
Auto - the vendor will be detected.
Avocent-Cyclades - Avocent-Cyclades PM PDU family.
SPC - SPC power control device family.
Server Tech - Server Tech family.
Default: Auto.
Enable Speed Auto
Detection
When enabled, detects the speed of the port. Default: Disabled.
Pooling Rate The interval in seconds to update information from the PDU. Default: 20.
For Avocent/Cyclades
PDUs
Power Cycle Interval
The interval in seconds between Off and On actions for the power cycle command.
Default: 15.
Syslog
When enabled, the PDU will send syslog messages to the appliance. Default:
Enabled.
Buzzer Enables or disables the PDU’s buzzer. Default: Enabled.
SW Overcurrent
Protection
When enabled, the software’s overcurrent protection is on. Default: Disabled.
To copy/clone the configuration of one port to other ports:
1. Select Ports - Serial Ports.
2. Click the checkbox for the serial port you want to clone.
3. Click the Clone button.
4. Enter the serial port(s) to be configured in the Copy Configuration To field and click Save.
NOTE: If the selected port is configured as a CAS Profile, the following parameters will not be copied: Port
Name, TCP Port Alias, IPv4 Port Alias, IPv6 Port Alias and Power (merged outlets).
To reset one or more serial ports to their factory configuration:
1. Select Ports - Serial Ports.
2. Click the checkbox for one or more serial ports you want to reset to their factory configuration,
then click the Reset To Factory button.
NOTE: Serial ports are set to the CAS Profile and disabled in the factory configuration.