User Guide
Accessing the Console Server via the Web Manager.....37
l. Use the drop-down menus to enable or disable log in/out multisession notification and
informational message notification.
5. Click Next or click the Data Buffering link and use the drop-down menus to enable and
configure data buffering.
6. Click Next or click the Alerts link.
a. Click Enable Alerts to enable detection of alerts.
b. Click Add to add an alert string. In the Alerts String field, enter the string. In the Script
field, enter the shell script that will run when the match happens. Click Next to return to
the Alerts screen.
NOTE: The console server allows an administrator to associate one shell script to the alert string. When
there is a match with the alert string, the console server will call the script passing the port number and the
line where the match occurs as arguments.
c. Check the box next to an existing alert and click Delete to delete the string.
d. Click Delete Any to delete all strings whether selected or not.
NOTE: Clicking Delete Any will delete all alert strings. Selecting all the alert strings and clicking Delete is
not the same functon as it will not delete alert strings not shown in the table.
7. Click Next or click the Power link.
a. Click Add to add a new outlet. Click Selected PDU and select a PDU from the list of
detected PDUs. Enter the outlet(s) in the Outlets field, and click Next.
b. Check the box next to an existing merged outlet and click Delete to delete it.
NOTE: Power is only available when a single serial port is selected.
8. Click Save.
Parameter Description
Physical
Enable Cisco
RJ-45 Pin-Out Defines the serial port pinout. Default: Disabled.
Status Defines the status of the serial port as either enabled or disabled. Default: Disabled.
Speed
Defines the speed as 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 or 230400.
Default: 9600.
Parity Defines the parity as either Even, Odd or None. Default: None.
Data Bits Defines the data bits as either 5, 6, 7 or 8. Default: 8.
Stop Bits Defines the stop bits as either 1 or 2. Default: 1.
CAS Profile Parameters