Power Switching & Controls for Business-Critical Continuity
4-hour protection no matter when trouble strikes ASCO S eries 300 Power Transfer Switches for Power Outage Protection Where would you be without a constant flow of electrical power? We often take for granted that power will always be around when we need it. In reality, power failures are very common. And when the power goes out, your business suffers. Power failures are unpredictable.
Typical Applications Telecom Agriculture In the telecommunications industry, providing a high level of service and dependability is crucial. Lost power means an interruption in service for your customers and lost business for your company. For instance, with cell sites scattered across a wide geographical region and in many remote areas, the chances of an interruption in power are increased, making Automatic Transfer Switches a valuable resource at each location.
Series 300 Power Transfer Switches Maximum Reliability & Excellent Value With a Series 300 Transfer Switch, you get a product backed by ASCO Power Technologies, the industry leader responsible for virtually every major technological advance in the Transfer Switch industry. The ASCO Series 300 was designed for one purpose–to automatically transfer critical loads in the event of a power outage. Each and every standard component was designed by ASCO engineers for this purpose.
Series 300 Power Transfer Switches Designed to Fit Anywhere The ASCO Series 300 product line represents the most compact design of automatic power transfer switches in the industry. With space in electrical closets being at a premium, the use of wall or floor-mounted ASCO Power Transfer Switches assures designers optimum utilization of space. All transfer switches through 2000 amps are designed to be completely front accessible.
Series 300 Microprocessor Controller The ASCO Microprocessor Controller is used with all sizes of Power Transfer Switches. It represents the most reliable microprocessor controller in the industry and includes, as standard, all of the voltage, frequency, control, timing and connectivity functions required for most emergency and standby power applications. Voltage & Frequency Sensing Adjustable three-phase, close-differential voltage sensing on normal source.
Series 300 Microprocessor Controller Battery to Maintain Engine Exerciser Clock Settings Re-transfer to Normal Adjustable Time Delay Simple and Accurate Adjustment of Voltage, Frequency and Time-Delay Settings Without Need for Meters and Variable Power Supplies Transfer to Emergency Adjustable Time Delay Dip Switches for Enabling Built-In Control Functions Serial Communication Port Customer Control Interfaces Fig.
Series 300 ATS Optional Accessories Accessory 11BG A programmable engine exerciser that provides for weekly or bi-weekly operation, includes one form C contact for source availability of normal and one contact for availability of emergency (contact rating 2 amps @ 30 Vdc, 0.5 amp @ 125 Vac resistive). The programmable engine exerciser incorporates a 7 day or 14 day time base with a digital readout display. Includes “with or without” load control selection for exerciser period.
Series 386 Non-Automatic Power Transfer Switches User-Initiated Control ASCO 386 non-automatic transfer switches are generally used in applications where operating personnel are available and the load is not an emergency type requiring automatic transfer of power. The power-switching mechanism and controller is the same hardware used on the highly reliable ASCO Series 300 transfer switches. ASCO 386s are furnished as standard with a momentary-type selector switch to initiate transfer and re-transfer.
Series 300 & 386 Transfer Switch Ordering Information To order an ASCO Series 300 Power Transfer Switch, complete the following catalog number: 300 + B + Product Neutral Code Voltage Code Continuous rating 3 poles, 30, 70, 104, 150, 2004, 3Ø 2304, 260, 400, 600, 800, 1000, 1200, 1600, 2000 26005, 30005 1 Switched Neutral N + Amperes 2 poles, 1Ø Solid Neutral B 600 Poles Blank 300 3 + A3 B3 C D E F H J K L M N Q R 1 + X + C + Enclosure Options Controller + Blank Open Type Inse
Series 300 & 386 Transfer Switch Dimensions and Shipping Weights UL Type 1 Enclosure4 Switch Rating Amps Phase Poles Neutral Code Width 2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 3 3 3 3 A B A B A B3 or C A B3 or C A B A B A B A B A B A B A B A B 17 1/2 (445) 17 1/2 (445) 17 1/2 (445) 17 1/2 (445) 18 (457) 18 (457) 18 (457) 18 (457) 24 (610) 24 (610) 24 (610) 24 (610) 34 (864) 34 (864) 34 (864) 34 (864) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 30, 70, 100*, 104 150, 200 *S
Series 300SE Power Transfer Switch The ASCO Service Entrance Power Transfer Switch combines automatic power switching with the necessary disconnecting, grounding, and bonding required for use as service entrance equipment. The power transfer switch meets all National Electrical Code requirements for service entrance use. Transfer switches generally are installed at facilities that have a single utility feed and a single emergency power source.
Series 300SE Transfer Switch Dimensions and Shipping Weights UL Type 1 Enclosure4 Switch Rating Amps Dimensions, In. (mm) Height Phase Poles Neutral Code Width 2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 3 3 3 3 STD B STD B STD C STD C STD B STD B STD B STD B STD B STD B 36.5 (927) 36.5 (927) 36.5 (927) 36.5 (927) 36.5 (927) 36.5 (927) 36.5 (927) 36.
Series 300L Power Transfer Load Center • Conventional double throw transfer switch configuration • Automatic Transfer Switch is listed to UL1008, the standard for Transfer Switch Equipment, and meets NFPA 110 for Emergency and Standby Power Systems and the National Electrical Code (NEC) Articles 700, 701, and 702. Also certified to CSA 22.2 No.
300L Power Transfer Switch Ordering Information 300 + L4 + Product 300 2 200 + Load Center Poles 4 = 42 Space 2 poles, 1Ø F + Amperes 3 poles, 3Ø C 208 F 240 5 X + Controller Voltage Code Continuous Rating 200 400 + 1 C + Options Insert “X” if optional accessories are required + Enclosure C M 73TL1 Optional Accessories Type 1 (Standard) 11BG - Programmable Engine Exerciser Type 3R Secure (Outdoor) 14AA/14BA - Auxiliary Contacts (2 Sets)1 37P - Generator Receptacle 2 + 24
PowerQuest 5700 Critical Power Management System ® 18
Emerson Network Power. The global leader in enabling Business-Critical ContinuityTM. EmersonNetworkPower.com Outside Plant AC Power Connectivity Embedded Computing Embedded Power DC Power Infrastructure Management & Monitoring Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2013 Emerson Electric Co. Publication 1195 R14.