7000 series Designed to Fit Anywhere*
Notes:
1. Enclosures are free-
standing with removable top,
sides, and back.
2. Consult ASCO for dimen-
sions on enclosures other
than UL type 1.
3. Order accessory 40MY for
1600A and 40NY for 2000A
front connected design.
Closed Transition and Delayed Transition Transfer Switching
7A DTS, 7A CTS, 7N DTS, 7N CTS
Shipping Weights
Notes:
1. Open weights include
transfer switch and control
panel. 1200-4000 amp
enclosures require ventilation
openings, refer to drawings
for details. Export shipments
may require a wooden box,
contact ASCO for weights and
dimensions.
24
Depth
inches (mm)
Height
inches (mm)
Width
inches (mm)
Poles
Switch Rating
Amps
Enclosed UL Type 1
2
150, 260, 400 2, 3 or 3 with neutral A/B 24 (610) 56 (1422) 14 (356)
600 2, 3 or 3 with neutral A/B 24(610) 63 (1600) 17(432)
800, 1000 2, 3 or 3 with neutral A/B 34 (864) 72 (1829) 20 (508)
1200 2, 3 or 3 with neutral A/B 38 (965) 87 (2210) 23 (584)
1600, 2000
1
2, 3 or 3 with neutral A/B 38 (965) 91 (2311) 48 (1219)
1600, 2000
3
(front connected) 2, 3 or 3 with neutral A/B 38 (965) 87 (2210) 23 (584)
3000
1
2, 3 or 3 with neutral A/B 38 (965) 91 (2311) 60 (1524)
4000
1
2, 3 or 3 with neutral A/C
60 (1524)
91 (2311) 72 (1829)
Open Configuration
150, 260, 400 2, 3 or 3 with neutral B 18-1/2 (470) 25 (635) 8 (203)
600 2, 3 or 3 with neutral B 19 (483) 30 (762) 9-7/8 (251)
800, 1000, 1200 2, 3 or 3 with neutral B 27 (686) 31 (787) 12-7/8 (327)
1600, 2000 2, 3 or 3 with neutral B 33-1/4 (845) 28 (711) 26-1/4 (667)
2600, 3000 2, 3 or 3 with neutral B 33-1/4 (845) 28 (711) 30-3/4 (781)
4000 2, 3 or 3 with neutral C 60 (1524) 70 (1778) 53 (1272)
Open*
lb (kg)
Enclosed*
lb (kg)
Poles
Switch Rating
Amps
150, 260, 400 2 275 (125) 160 (73)
150, 260, 400 3 280 (127) 165 (75)
150, 260, 400 3 with B 295 (134) 175 (79)
600 2 345 (157) 235 (107)
600 3 350 (159) 235 (107)
600 3 with B 365 (166) 245 (111)
800, 1000 2 505 (229) 300 (136)
800, 1000 3 510 (232) 305 (138)
800, 1000 3 with B 525 (238) 315 (143)
1200 2 695 (316) 330 (150)
1200 3 700 (318) 335 (152)
1200 3 with B 715 (325) 345 (157)
1600, 2000 2 1305 (592) 545 (247)
1600, 2000 3 1325 (602) 545 (247)
1600, 2000 3 with B 1345 (611) 565 (257)
2600, 3000 2 1465 (665) 645 (293)
2600, 3000 3 1485 (674) 645 (293)
2600, 3000 3 with B 1505 (683) 665 (302)
4000 2 2715 (1233) 1645 (747)
4000 3 2735 (1242) 1665 (756)
4000 3 with B 2755 (1251) 1685 (765)
Closed Transition and Delayed Transition Transfer Switching
7A DTS, 7A CTS, 7N DTS, 7N CTS
*All dimensions and weights
shown are approximate and
should not be used for
construction purposes.
Certified dimensions can be
furnished upon request.
*All dimensions and weights