User Guide

Viewing Battery and Monitor Status
21-10
21.9. Historical Graphs
String View > Cell voltage or Cell resistance or Intercell resistance
When the BMDM is displaying a String View Cell Voltage, Cell Resistance or Intercell Resistance
screen, you may save or view historical graphs.
String View > Save history record or File|Save history record
Save History Record - To save a history record of the graph and table values on the String View
screen, click Save History Record. This captures the readings, stamped with the date and time taken.
Figure 83. History Options and Record Date/Time Box
String View > Open history record or File|Open
Open - To display a historical graph and table on String View, click Open History Record, select a
date/time, and click OK. The graph and table appear, with the historical record date/time box at the
top right of the screen. You may step through historical records by clicking the left or right arrows.
String View > File|Close
Close - To close the history record and return to the active String View screen, click Close. (Do not
click the
X on the upper right corner.) The historical graph, record date/time box, and left/right arrows
close.
String View > File|Extract History then (optional) File|Open|date then File|Close
Extract History - Click Extract History to have the computer extract historic float data for the string
the computer is polling. To view the extracted data, click File|Open and select the date. If a date is not
listed, no new data was extracted on that date.
String View > File|Extract All then (optional) File|Open|date then File|Close
Extract All - This function is similar to the Extract All Data button on String Status, except String
View is displaying an active connection. Click Extract All to extract historic float data, resistance
data, and discharge data for the string being polled. To view the extracted data, click File|Open and
select the date. If a date is not listed, no new data was extracted on that date.