Table 2. Material Temperature Ratings
COMPONENT AND MATERIAL OF CONSTRUCTION
(1)
TEMPERATURE RANGE
_C _F
Valve Body
Carbon Steel (WCC or SA 516-70)
(5)
CF8M (316 SST) CL150
CF8M FMS 20B16 (0.04% min. carbon) CL300
29 to 427
198 to 538
198 to 816
20 to 800
325 to 1000
325 to 1500
Disc
CF8M (316 SST) w/ or w/o Hard coating
CF8M with CoCr-A edge (Alloy 6)
198 to 538
198 to 816
325 to 1000
325 to 1500
Shaft
S20910
S17400 (17-4 PH 1025)
S17400 (17-4 PH H1150M)
198 to 538
73 to 454
196 to 454
325 to 1000
100 to 850
320 to 850
Bearings
PEEK
(2)
(standard)
S31600
(3)
73 to 260
198 to 816
100 to 500
325 to 1500
Packing
PTFE Packing and PTFE ENVIRO-SEAL Packing
Graphite packing
Graphite packing with oxidizing media
54 to 232
198 to 916
198 to 538
65 to 450
325 to 1500
325 to 1000
Seal Ring and
Backup Ring
PTFE Seal Ring
Nitrile Backup O-Ring
Chloroprene Backup O-Ring
EPR Backup O-Ring
Fluorocarbon Backup O-Ring
PTFE Backup O-Ring
29 to 93
43 to 149
54 to 182
29 to 204
73 to 204
20 to 200
45 to 300
65 to 360
20 to 400
100 to 400
UHMWPE
(4)
Seal Ring (CL150 Only)
Nitrile Backup O-Ring
Chloroprene Backup O-Ring
EPR Backup O-Ring
Fluorocarbon Backup O-Ring
PTFE Backup O-Ring
29 to 93
43 to 93
54 to 93
29 to 93
73 to 93
20 to 200
45 to 200
65 to 200
20 to 200
100 to 200
Phoenix III and/or FireTested Construction
S31600 and PTFE Seal Ring with Nitrile Backup O-Ring
Chloroprene Backup O-Ring
EPR Backup O-Ring
Fluorocarbon Backup O-Ring
40 to 149
54 to 149
62 to 204
40 to 232
40 to 300
65 to 300
80 to 400
40 to 450
Seal Ring
NOVEX S31600 Seal
(3)
Ring (CL150)
NOVEX S31600 Seal
(3)
Ring (CL300)
NOVEX S21800 Seal Ring (CL300)
46 to 538
46 to 816
46 to 816
50 to 1000
50 to 1500
50 to 1500
1. NACE trim constructions are available; consult your Emerson Process Management sales office.
2. PEEK stands for poly-ether-ether-ketone.
3. For a complete material description, contact your Emerson Process Management sales office.
4. UHMWPE stands for ultra high molecular weight polyethylene.
5. Cast or wrought/plate grades used interchangeably, depending upon availabilityunless specified by customer.
Installation
The valve is normally shipped as part of a control
valve assembly, with the power actuator mounted on
the valve. If the valve or actuator have been
purchased separately, or if the actuator has been
removed for maintenance, mount the actuator on the
valve, and adjust actuator travel before installing the
valve into the line. This is necessary due to the
measurements that must be made during the
actuator calibration adjustment process. Refer to the
Actuator Mounting section of this manual and to the
separate actuator instruction manual for mounting
and adjusting instructions before proceeding.
WARNING
To avoid personal injury or property
damage resulting from the sudden
release of pressure:
D Always wear protective gloves,
clothing, and eyewear when
performing any maintenance
operations to avoid personal injury.
D Do not install the valve assembly
where service conditions could exceed