Technical data
Configuring and Operating the System
AXP 1410 Installation and Use (6806800H70D)
89
Virtual Standby IP Address on Out-of-Band Interface
To avoid an address conflict between out-of-band and backplane interfaces, 100 is added to
the third octet of all out-of-band interface IP addresses, if any of them would be equal to one of
the backplane addresses otherwise.
Changing the Shelf Manager Virtual IP Address for the Out-of-Band Interface
To change the Shelf Manager Virtual IP address:
z Modify the first two octets of the shelf IP connectivity Record #1
or
z Change the shelf address
or
z Modify the first two octets of the shelf IP connectivity Record #1 and also change the shelf
address
Refer Setting the Shelf Geographical Address on page 84, to see how you can change the shelf
address.
1. Change the first two octets of the IP address using the hpiship tool located on the
shelf manager. Use the option -h for help.
2. Change the third octet of the IP address by changing the shelf address.
3. Reboot the system for the changes to take effect.
Netmask of IP1 Virtual Standby IP Address Default Value
255.0.0.0 <IP1_1>.<IP1_2>.<SGA>.181 192.168.0.181
255.255.0.0
255.255.255.0
If the third octet of the IP address is changed using hpiship, it is temporary and will be
changed automatically on the next reboot to match the shelf address.