Technical data

FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70D)
159
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3F3F Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable
Reading Type Unsigned
Lower Non-Critical, Critical and
Non-Recoverable thresholds
0xD4, 0xCA, 0xC1 (11.024, 10.504, 10.036) Volts
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xFA, 0xFF, 0xFF (13, 13.26, 13.26) Volts
Table 7-44 Sensor No. 13, 48.0V FEED_1
Feature Raw Value/Description Interpreted Value
Sensor Name 48.0V FEED_1
Device
Sensor Type 0x02 Voltage
Class 0x01 Threshold
Sensor Owner LUN 0x00
Entity ID 0x0A Power Supply
Entity Instance 0x60
Rearm mode Auto
Hysteresis support Readable/Settable
Threshold access support Readable/Settable
Event message control Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3F3F Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable
Reading Type Unsigned
Lower Non-Critical, Critical and
Non-Recoverable thresholds
0x84, 0x77, 0x71 (42.24, 38.08, 36.16) Volts
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xE1, 0xEB, 0xEE (72, 75.20, 76.16) Volts
Table 7-43 Sensor No. 5 +12V CC (continued)
Feature Raw Value/Description Interpreted Value