Technical data
FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70D)
158
Entity Instance 0x60
Rearm mode Auto
Hysteresis support Readable/Settable
Threshold access support Readable/Settable
Event message control Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3F3F Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable
Reading Type Unsigned
Lower Non-Critical, Critical and
Non-Recoverable thresholds
0xDF, 0xDA, 0xD1 (4.8168, 4.7088, 4.5144) Volts
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xF6, 0xFA, 0xFF (5.3136, 5.4, 5.508) Volts
Table 7-43 Sensor No. 5 +12V CC
Feature Raw Value/Description Interpreted Value
Sensor Name +12V CC
Device
Sensor Type 0x02 Voltage
Class 0x01 Threshold
Sensor Owner LUN 0x00
Entity ID 0x0A Power Supply
Entity Instance 0x60
Rearm mode Auto
Hysteresis support Readable/Settable
Threshold access support Readable/Settable
Event message control Entire Sensor only
Table 7-42 Sensor No. 4 +5V Measure (continued)
Feature Raw Value/Description Interpreted Value