Technical data
FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70D)
157
Table 7-41 Sensor No. 3 +12V Measure
Feature Raw Value/Description Interpreted Value
Sensor Name +12V Measure
Device
Sensor Type 0x02 Voltage
Class 0x01 Threshold
Sensor Owner LUN 0x00
Entity ID 0x0A Power Supply
Entity Instance 0x60
Rearm mode Auto
Hysteresis support Readable/Settable
Threshold access support Readable/Settable
Event message control Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3F3F Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable
Reading Type Unsigned
Lower Non-Critical, Critical and
Non-Recoverable thresholds
0xD4, 0xCA, 0xC1 (11.024, 10.504, 10.036) Volts
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xFA, 0xFF, 0xFF (13, 13.26, 13.26) Volts
Table 7-42 Sensor No. 4 +5V Measure
Feature Raw Value/Description Interpreted Value
Sensor Name +5V Measure
Device
Sensor Type 0x02 Voltage
Class 0x01 Threshold
Sensor Owner LUN 0x00
Entity ID 0x0A Power Supply