Technical data

FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70D)
156
7.3.5.1 Voltage Sensors
The following sensors measure voltages of the PEM.
Table 7-40 Sensor No. 2 +3.3V
Feature Raw Value/Description Interpreted Value
Sensor Name +3.3V
Device
Sensor Type 0x02 Voltage
Class 0x01 Threshold
Sensor Owner LUN 0x00
Entity ID 0x0A Power Supply
Entity Instance 0x60
Rearm mode Auto
Hysteresis support Readable/Settable
Threshold access support Readable/Settable
Event message control Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3F, 0x3F Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable
Reading Type Unsigned
Lower Non-Critical, Critical and
Non-Recoverable thresholds
0xD8, 0xD4, 0xD1 (3.1104, 3.0528, 3.0096) Volts
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xF4, 0xF7, 0xFA (3.5136, 3.5568, 3.6) Volts