Technical data
FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70D)
154
7.3.3 Power Configuration
The next table describes the power configuration for the PEMs.
7.3.4 Power Entry Module Sensor Overview
The following table lists all IPMI sensors available on the Power Entry Module.
Table 7-38 Power Configuration for PEMs
Item Value Description
Dynamic power reconfiguration support No Possibility to change FRU power consumption
without switching it off, according to
AdvancedTCA
Dynamic power configuration No Are the power draw levels fixed or these may vary
if additional components are hot inserted or
onboard component power consumption is
changing dynamically
Number of power draw levels 1 The amount of possible power levels, normally 1
Early power draw levels, watt 0.1 Complete early power level including IPMC
Steady state power draw levels, watt 0.1 Complete steady power consumption including
IPMC
Transition from early to steady levels in
seconds
0 How long does board consume early power. Early
power is normally bigger than steady power
Table 7-39 IPMI Sensors on the PEM
Sensor
No. Sensor Name
Type of
Measurement What does it measure? Sensor Type Availability
0 Hot Swap Status State of FRU Discrete Always
1 IPMB Physical Status State of IPMB link Discrete Always
2 +3.3V Voltage Analog Always
3 +12V Measure Voltage Analog Always
4 +5V Measure Voltage Analog Always
5 +12V CC Voltage