7.2.3 Fan Tray Module Discrete Sensors
The following tables describe these discrete sensors available on the FTM:
z Hot Swap Sensor
z IPMB Link Sensor
z Reserved Sensor
z OEM-Reserved Sensors
Table 7-24 Sensor No. 19 Fan 6 Outlet
Feature Raw Value/Description Interpreted Value
Sensor Name Fan 6 Outlet
Device
Sensor Type 0x04 Fan
Class 0x01 Threshold
Sensor Owner LUN 0x00
Entity ID 0x1D Cooling Unit
Entity Instance 0x63
Rearm mode Auto
Hysteresis support Readable/Settable
Threshold access support Readable/Settable
Event message control Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3F3F Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable
Reading Type Unsigned
Lower Non-Critical, Critical and
Non-Recoverable thresholds
0x24, 0x24, 0x24 (902, 902, 902) RPM
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xCE, 0xE6, 0xF2 (5588, 5610, 5610) RPM