Technical data
Chapter 7
AXP 1410 Installation and Use (6806800H70D)
123
FRU Information and Sensor Data Records
7.1 Introduction
This chapter introduces FRU information, e-keying, sensor overviews, and power configuration
data for PEMs and upper and lower fan tray module of the AXP 1410 system. Information in this
chapter includes:
z Fan Tray Module Sensor Data Records
z Power Entry Module Sensor Data Records
7.2 Fan Tray Module Sensor Data Records
This section describes in detail all available IPMI sensors of the Fan Tray Module.
7.2.1 Fan Tray Module Sensor Overview
The following table lists all IPMI sensors available on the Fan Tray Module.
Table 7-1 IPMI Sensors on the Fan Tray Module
Sensor
No. Sensor Name
Type of
Measurement What does it measure? Sensor Type Availability
0 Hot Swap Status State of FRU Discrete Always
1 Version Change Version change OEM Version Use Discrete Always
2 IPMB Link State of IPMB link Discrete Always
3 +12V A_MON Voltage Fan 12V source A Threshold Always
4 +12V B_MON Voltage Fan 12V source B Threshold Always
5 +3.3V Voltage 3.3V output Threshold Always
6 +5V A_MON Voltage 5V source A Thresholdd Always
7 +5V B_MON Voltage 5V source B Threshold Always
8 Fan 1 Fan Fan Unit 1 Inlet Fan RPM Threshold Always
9 Fan 2 Fan Fan Unit 2 Inlet Fan RPM Threshold Always
10 Fan 3 Fan Fan Unit 3 Inlet Fan RPM Threshold Always
11 Fan 4 Fan Fan Unit 4 Inlet Fan RPM Threshold Always