Data Sheet

Bulletin 71.1:133
20
Table 10. Type 133HP Regulator 60% Capacities in Thousands of SCFH of 0.6 Specic Gravity Gas at 14.7 psia and 60°F (continued)
OUTLET PRESSURE
RANGE, CONTROL
SPRING NUMBER,
AND COLOR
OUTLET
PRESSURE
SETTING
(1)
INLET
PRESSURE
2-INCH / DN 50 BODY SIZE
1.91-INCH / 48.5 mm ORIFICE SIZE
Droop from Setpoint
10% 20% 30%
psig bar psig bar SCFH Nm
3
/h SCFH Nm
3
/h SCFH Nm
3
/h
26 to 40 psig /
1.8 to 2.8 bar
10C1241X012
Blue
30 2.1
35
40
60
80
100
125
150
2.4
2.8
4.1
5.5
6.9
8.6
10.3
25.0
31.9
53.4
71.9
89.3
110.5
131.4
0.67
0.86
1.43
1.93
2.39
2.96
3.52
50.7
62.1
99.7
132.8
164.5
203.1
241.2
1.36
1.66
2.67
3.56
4.41
5.44
6.46
55.7
66.0
101.8
134.3
165.6
203.9
241.8
1.49
1.77
2.73
3.60
4.44
5.46
6.48
40 2.8
45
50
60
80
100
125
150
3.1
3.4
4.1
5.5
6.9
8.6
10.3
38.5
48.0
63.9
90.8
115.0
144.0
172.1
1.03
1.29
1.71
2.43
3.08
3.86
4.61
60.5
72.1
92.5
128.1
161.0
200.5
239.1
1.62
1.93
2.48
3.43
4.32
5.37
6.41
67.1
77.5
96.4
130.7
162.9
201.9
240.2
1,80
2,08
2,58
3,50
4,37
5,41
6,44
36 to 50 psig /
2.5 to 3.4 bar
10C1242X012
Green
40 2.8
45
50
60
80
100
125
150
3.1
3.4
4.1
5.5
6.9
8.6
10.3
31.2
38.8
51.5
73.1
92.6
115.8
138.5
0.84
1.04
1.38
1.96
2.48
3.10
3.71
60.5
72.1
92.5
128.1
161.0
200.5
239.1
1.62
1.93
2.48
3.43
4.32
5.37
6.41
67.1
77.5
96.4
130.7
162.9
201.9
240.2
1.80
2.08
2.58
3.50
4.37
5.41
6.44
50 3.4
55
60
80
100
125
150
3.8
4.1
5.5
6.9
8.6
10.3
44.2
53.9
84.8
110.9
140.9
169.7
1.18
1.44
2.27
2.97
3.78
4.55
70.3
82.1
121.7
156.4
197.1
236.5
1.88
2.20
3.26
4.19
5.28
6.34
78.6
89.0
125.9
159.4
199.3
238.2
2.11
2.38
3.37
4.27
5.34
6.38
45 to 60 psig /
3.1 to 4.1 bar
10C1243X012
White
50 3.4
55
60
80
100
125
150
3.8
4.1
5.5
6.9
8.6
10.3
37.3
45.4
71.4
93.2
118.4
142.6
1.00
1.22
1.91
2.50
3.17
3.82
70.3
82.1
121.7
156.4
197.1
236.5
1.88
2.20
3.26
4.19
5.28
6.34
78.6
89.0
125.9
159.4
199.3
238.2
2.11
2.38
3.37
4.27
5.34
6.38
60 4.1
65
70
80
100
125
150
4.5
4.8
5.5
6.9
8.6
10.3
50.0
59.9
77.0
105.8
137.5
167.4
1.34
1.60
2.06
2.84
3.68
4.49
80.1
92.0
113.2
150.5
192.9
233.2
2.15
2.47
3.03
4.03
5.17
6.25
90.1
100.5
119.8
155.0
196.2
235.8
2.42
2.69
3.21
4.15
5.26
6.32
1. Outlet pressure setting was made at approximately 10% of the maximum capacity for the listed conditions.
Grayareasindicatemaximumowcapacity.