Specifications

152 Model 2700 Transmitter with PROFIBUS-PA
Model 2700 PROFIBUS Block Parameters
20 ALERT_KEY This parameter contains the
identification number of the plant
unit.
SIMPLE Unsigned8 1 S 0 R/W NA NA
21 TARGET_MODE This parameter contains desired
mode normally set by a control
application of an operator. The
modes are valid alternatively only,
i.e. only one mode can be set at
one time. A write access to this
parameter with more than one
mode is out of the range of the
parameter and has to be rejected.
SIMPLE Unsigned8 1 S AUTO
(0x08)
R/W AUTO ( 0x08) NA
22 MODE_BLK This parameter contains the
current mode and the permitted
and normal mode of the block.
RECORD DS-37 3 D --- R NA NA
23 ALARM_SUM This parameter contains the
current states of the block alarms.
RECORD DS-42 8 D 0,0,0,0 R NA NA
Physical block parameters
24 SOFTWARE_REVISION
(DD Name: Software Revision)
Revision-number of the software
of the field device.
Simple Visible String 16 Cst --- R NA R-1200
25 HARDWARE_REVISION
(DD Name: Hardware
Revision)
Revision-number of the hardware
of the field device.
Simple Visible
String
16 Cst 1.0 R NA
Hard Coded
26 DEVICE_MAN_ID
(DD Name: Manufacturing ID)
Identification code of the
manufacturer of the field device.
Simple Unsigned16 2 Cst ---- R NA R-121
27 DEVICE_ID (DD Name: Device
ID)
Manufacturer specific identification
of the device.
Simple Visible String 16 Cst ---- R NA 2545-2554
28 DEVICE_SER_NUM
(DD Name: PB Serial Number)
Serial number of the field device. Simple Visible String 16 Cst ---- R NA R122-123
29 DIAGNOSIS(DD Name:
Physical Block Diagnosis)
Detailed information of the device,
bitwise coded. More than one
message
possible at once. If MSB of byte 4
is set to 1 than more diagnose
information is
available in the
DIAGNOSIS_EXTENSION
parameter.
Simple Octet String
byte4,MSB=1
more diag
available
4 D ---- R Refer byte 11 to 14
of Extended
Diagnostics bytes
in Appendix A
NA
30 EMPTY
31 DIAGNOSIS_MASK(DD
Name: Diagnosis Mask)
Definition of supported
DIAGNOSIS information-bits.
Simple Octet string 4 Cst ---- R Out of Mandatory
Alarms out of 4
Octets only Ident
No. violation Alarm
is supported.
And Extension
Available Alarm is
supported
0: not supported
1: supported
Hard Coded
0x00
0x80
0x00
0x80
32 EMPTY
33 EMPTY
34 EMPTY
35 EMPTY
36 Reserved
37 Reserved
38 DEVICE_INSTALL_DATE Device Installation Date Simple Octect String 16 S Blank R/W 2278-2285
40 IDENT_NUMBER_
SELECTOR
(DD Name: Ident Number)
Each PROFIBUS-DP /IEC 61158/
device shall have an
Ident_Number provided by
the PNO. There are profile specific
Ident_Numbers. A device may
have profile
specific and manufacturer specific
ones. The user is able to choose
one of these
using this parameters.
Simple Unsigned8 1 S ---- R/W 0: profile specific
Ident_Number
V3.01 (mandatory)
1: manufacturer
specific
Ident_Number
V3.01
NA
42 FEATURE
(DD Name: phys Feature)
Indicates optional features
implemented in the device and the
status of these
Features which indicates if the
feature is supported or not
supported.
Record DS-68 8 N 0x03,
0x00,
0x00,
0x00,
0x02,
0x00,
0x00,
0x00
RPROFIBUS
Specification
June 2005
Order No: 3.042
Amendment 2
to
the Profibus Profile
for Process
Control Devices V
3.01
Condensed Status
and Diagnostic
Messages
V 1.0
NA
Table F-2 Physical block parameters (continued)
Index Parameter Mnemonic Definition Message
Ty pe
Data Type/
Structure
Size Store
/Rate
(HZ)
Default
Value
Access Enumerated List of
Values / Range
Modbus
Register /
Coil