User Manual

Daniel 3814 Liquid Ultrasonic Meter Installation Manual Section 3: Electrical installation
3-9000-760 Rev E March 2015
Frequency/Digital outputs 53
Output for FODO1 and Digital Output1 (Group 1 on the CPU Module) share a common ground
and have 50V isolation. FODO2 and FODO3 (Group 2 on the CPU Module) share a common
ground and have 50V isolation. This allows an output to be connected to a different flow
computer. The outputs are opto-osculated from the CPU Module and have a withstand voltage
of at least 500V rms dielectric.
Figure 3-6 CPU Module - Frequency/Digital outputs common ground
Table 3-5 Frequency/Digital Outputs possible configurations
Frequency/Digital output Source configuration
Frequency /Digital Output 1
1
Frequency /Digital Output 2
2
or
Frequency /Digital Output 3
2
1. Solid blue line denotes valid selection for Frequency/Digital Output 1.
2. Black dashed -line denotes valid selections for Frequency/Digital Output 2 and Frequency/Digital
Output 3.
Frequency output 1A
Frequency output 1B
Digital output 1A
Digital output 1B
Frequency output 1A
Frequency output 1B
Digital output 1A
Digital output 1B
Frequency output 2A
Frequency output 2B
Digital output 2A
Digital output 2B
FODO1
FODO2
FODO3
FO1A
FO1B
DO1A
DO2B
FO2A
FO2B
DO2A
DO2B
A.
A. FODO1 and Digital input1 - shared common ground (Group 1)
B. FODO2 and FODO3 - shared common ground (Group 2)
B.