Daniel 3814 Liquid Ultrasonic Meter Installation Manual Section 1: Introduction
3-9000-760 Rev E March 2015
Safety 15
Daniel 3810 Series Liquid Ultrasonic Meters are INMETRO certified. Refer to the 3810 Series
Liquid Ultrasonic Flow Meter Tag, INMETRO Certification drawing DMC - 006173.
Certificate number: NCC 11.0163 X
Marking: --Ex d ia IIB T4 Gb IP66 W
Electrical parameters: Refer to Section 1.6, Table 1-2
Special conditions for safe use
Explosion proof joint dimensions are compliant with the Brazilian Association of
technical standard: ABNT NBR IEC 60079-1, Table 3.
The enclosure for the explosion proof transmitter and intrinsically safe barrier must be
remote mounted (refer to Section 1.6, Table 1-2)
if the operating temperature exceeds 1
40
o
F (60
o
C) (refer to Section 1.6, Table 1-2)
Cable length (refer to Section 1.6, Table 1-2)
EXPLOSION OR FIRE HAZARD
READ AND FOLLOW THE WARNINGS BELOW:
Conduit runs must have a sealing fitting within 457mm (18 inches) of the enclosure to reduce the
risk of an explosion or a fire.
During operation, keep covers tightly closed. DO NOT open the assembly when an explosive
atmosphere may be present.
During equipment maintenance, disconnect power before opening transmitter or base
electronics. Clean cover joints before replacing.
DO NOT substitute meter components. Substituting components may compromise the intrinsic
safety.
Failure to follow these safety instructions may result in severe injury to personnel or cause damage to
th i t