Selection Guide
PCN Description Connection
Flow Capacity Tons @ 1 psi ∆P
14
(For kW, multiply tons by 3.5)
Water Capacity
2
Drops of Water
3
R-12 R-134a R-22 R-407C R-404A/R-507 R-502
R-12 R-134a R-22 R-407C R-404A/R-507 R-502 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F
064388 CU 03 2 S 1/4 ODF 1.4 1.7 1.8 1.8 1.2 1.2
96 87 93 87 87 81 72 57 96 93 90 81
064389 CU 03 3 S 3/8 ODF 2.1 2.6 2.8 2.7 1.9 1.8
064390 CU 05 2 S 1/4 ODF 1.5 1.8 2.0 2.0 1.3 1.3
112 101 108 101 101 93 82 63 112 108 104 93
064391 CU 05 3 S 3/8 ODF 2.1 2.6 2.8 2.7 1.9 1.8
064392 CU 08 2 S 1/4 ODF 1.6 1.9 2.1 2.1 1.4 1.4
212 191 205 191 191 177 156 122 212 205 198 177064393 CU 08 3 S 3/8 ODF 2.9 3.5 3.8 3.7 2.5 2.5
064394 CU 08 4 S 1/2 ODF 3.5 4.2 4.6 4.5 3.1 3.0
064395 CU 16 3 S 3/8 ODF 3.3 4.0 4.3 4.2 2.9 2.8
287 257 277 257 257 237 207 158 287 277 267 237064396 CU 16 4 S 1/2 ODF 3.9 4.7 5.1 5.0 3.4 3.3
064397 CU 16 5 S 5/8 ODF 4.4 5.4 5.8 5.7 3.9 3.8
Emerson Climate Technologies148
Solenoid
Valves
Temperature
Pressure Controls
Coils
Industrial
Solenoid Valves
Shut Off
Valves
System
Protectors
Storage
Devices
Oil
Controls
Pressure
Regulators
Competitive Cross
Reference
Thermal
Expansion Valves
Spun Copper Liquid Line Filter-Drier
Features
The CU series is a high capacity spun copper solid core lter-
drier ideal for superior corrosion resistance in ocean going
vessels and coastal applications.
Nomenclature
Specications
CU 16 3 S
Series Unit Size Connection Size
(in 1/8”)
ODF
Ordering Information and Capacity Tables
Dimensional Data (in)
• All copper construction for extreme corrosion resistance
• 100% molecular sieve solid core drier
• For use with CFC, HCFC and HFC refrigerants
• Maximum working pressure: 500 psig
• Filtration: 40 microns
• UL/CUL le number: SA 7175
1
All ratings in accordance with ARI Standard 710-04. 86
o
F liquid refrigerant temperature
2
Water Capacities are based on:
3
20 drops of water = 1 gram = 1 cc
5
o
F saturated vapor temperature Equilibrium Point Dryness (EPD) of:
3.1 lbs./min./ton for R-134a 50 parts per million for R-134a, R404-A/507,
2.9 lbs./min./ton for R-22 and R-407C R-410A and R-407C
4
For 2 PSI ∆P, Multiply values by 1.4
4.0 lbs./min./ton for R-404A/507 and R-12 60 parts per million for R-22
4.4 lbs./min./ton for R-502 15 parts per million for R-12
2.7 lbs./min./ton for R-410A 30 parts per million for R-502
Description
Overall Length
(A)
Lay-In Dimension
(B)
Diameter
CU 03 3.94 3.25 1.63
CU 05 5.19 4.50 1.63
CU 08 6.06 5.38 2.00
CU 16 6.63 6.00 2.00
example: CU 163S