Product Overview

2004FC-118 R13 (01/14) Emerson Climate Technologies
SOL 19
Solenoid Valves & Coils
Voltage / Frequency Description PCN Description PCN Description PCN
24V 50/60 Hz
AHG 24V 50/60 Hz 057669 AMC 24V 50/60 Hz 057631 AMF 24V 50/60 Hz 057539
AMG 24V 50/60 Hz 057341 AHC 24V 50/60 Hz 057736 AMF 24V 50/60 Hz 057538
DMS 24V 50/60 Hz 062013
DMG 24V 50/60 Hz 055129 -- -- RMF 24V 50/60 Hz 065677
-- -- -- -- AMS 24V 50/60 Hz 057603
-- -- -- -- RMS 24V 50/60 Hz 065680
120V 50/60 Hz
AHG 120V 50/60 Hz 057673 AMC 120V 50/60 Hz 057598 RMF 120V 50/60 Hz 065678
AMG 120V 50/60 Hz 057331 AHC 120V 50/60 Hz 057743 AMS 120V 50/60 Hz 057349
DMG 120V 50-60 Hz 054762 -- -- RMS 120V 50/60 Hz 065204
208-220/208-240 50/60 Hz
AHG 208-220/208-240 50/60 Hz 057671 AHC 208-220/208-240 50/60 Hz 057741 AMF 208-220/208-240 50/60 Hz 057540
AMG 208-220/208-240 50/60 Hz 057342 AMC 208-220/208-240 50/60 Hz 057594 RMF 208-220/208-240 50/60 Hz 065679
DMG 208-220/208-240 50/60 Hz 054764 -- -- AMS 208-220/208-240 50/60 Hz 057531
-- -- -- -- RMS 208-220/208-240 50/60 Hz 065681
-- -- -- -- DMS 208-220/208-240 50/60 Hz 063399
480V 50/60 Hz AMG 480V 50/60 Hz 057527 -- -- AMF 480V 50/60 Hz 057534
120-240V 50/60 Hz AMG 120-240V 50/60 Hz 057343 AMC 120-240V 50/60 Hz 057730 AMF 120-240V 50/60 Hz 062410
277V 60 Hz
AMG 277V 60 Hz 057528 -- -- AMF 277V 50/60 Hz 057533
-- -- -- -- AMS 277V 50/60 Hz 057714
12V DC AMG 12V DC 057521 AMC 12V DC 057596 -- --
24V DC AMG 24V DC 057523 AMC 24V DC 057633 -- --
Ordering Information
ASC2 – DIN MMG
AMC - 1/2” ConduitAMG Junction Box
AMS - Open Frame
6” Leads
18” Leads
18” Leads or
1.4” Spades
Voltage/Frequency Description PCN Description PCN
24V 50/60 Hz ASC2 24/50-60 062792 -- --
24V 50/60 Hz ASC2L 24/50-60 063542 -- --
120V 50/60 Hz ASC2 120/50-60 062462 -- --
120V 50/60 Hz ASC2 GS-2562-1 015384 -- --
208-220/208-240 50-60 Hz ASC2 208-240/50-60 062463 -- --
208-220/208-240 50-60 Hz ASC2 GS-2562-2 015383 -- --
12V -- -- MMG 12V DC 063524
12V -- -- MMF 12V DC 062972
24V ASC2 24V DC 064375 MMG 24V DC 063526
AM and ASC 2 style DC coils should not
be used for direct replacements on OEM
equipment. The use of this coil on new
applications may result in the valve not
opening. New applications should use the
MM coil because of the signicant increase
in opening power of the MM Coil over the
standard AM and ASC 2 style DC coil.
Coil Enclosure Options
Options Code
Junction Box G
Conduit - 18” Leads C
Open Frame - 18” Leads F
Open Frame - Spades S
Dual Voltage Wiring Diagram
A B
120 240
240 480
Coils for Solenoid Valves
RMF