TXV Extended Capacity Tables
R-410A Conventional Valves (kWatts)– A Series
      Evaporator Temperature
  10°C  0°C  -10°C
  Nominal  Pressure Drop Across Valve (kPa)  Pressure Drop Across Valve (kPa)  Pressure Drop Across Valve (kPa)
Valve Type  Rating 750  1000  1100 1450 1700  2000 750  1000  1100  1450  1700 2000  750  1000 1100 1450  1700 2000
AA/AN/AAC/ANC  1/4  1.20  1.39  1.46  1.67  1.81  1.97  1.20  1.39  1.46  1.67  1.81  1.97  1.17  1.35  1.41  1.62  1.76  1.91
AA/AN/AAC/ANC/AFA  1/2  2.12  2.45  2.57  2.95  3.20  3.47  2.09  2.41  2.53  2.90  3.14  3.41  2.05  2.37  2.49  2.85  3.09  3.35
AA/AN/AAC/ANC/AFA  1  3.40  3.92  4.12  4.73  5.12  5.55  3.36  3.88  4.07  4.68  5.06  5.49  3.29  3.80  3.99  4.58  4.96  5.38
AA/AN/AAC/ANC/AFA  1-1/2  4.89  5.64  5.92  6.79  7.35  7.98  4.81  5.56  5.83  6.69  7.25  7.86  4.71  5.44  5.70  6.55  7.09  7.69
AA/AN/AAC/ANC/AFA  2  7.19  8.30  8.70  9.99  10.82  11.74  7.12  8.22  8.62  9.89  10.71  11.62  6.94  8.01  8.40  9.65  10.45  11.33
AA/AN/AAC/ANC/AFA  3  10.09  11.65  12.22  14.03  15.19  16.48  9.98  11.53  12.09  13.88  15.03  16.30  9.70  11.20  11.75  13.49  14.60  15.84
AA/AN/AAC/ANC/AFA  4  12.35  14.27  14.96  17.18  18.60  20.17  12.21  14.10  14.79  16.98  18.39  19.94  11.89  13.73  14.40  16.54  17.91  19.42
AA/AN/AAC/ANC  5  14.66  16.92  17.75  20.38  22.06  23.93  14.51  16.76  17.58  20.18  21.85  23.70  14.12  16.31  17.11  19.64  21.27  23.07
      Evaporator Temperature
  -20°C  -30°C  -40°C
  Nominal  Pressure Drop Across Valve (kPa)  Pressure Drop Across Valve (kPa)  Pressure Drop Across Valve (kPa)
Valve Type  Rating 1000 1100 1450 1700 2000  2300 1000  1100 1450 1700 2000 2300 1000 1100 1450 1700 2000 2300
AA/AN/AAC/ANC  1/4  1.20  1.26  1.45  1.57  1.70  1.83  0.85  0.89  1.02  1.11  1.20  1.29  0.57  0.59  0.68  0.74  0.80  0.86
AA/AN/AAC/ANC/AFA  1/2  2.12  2.23  2.56  2.77  3.00  3.22  1.45  1.52  1.75  1.89  2.05  2.20  0.96  1.00  1.15  1.25  1.35  1.45
AA/AN/AAC/ANC/AFA  1  3.36  3.53  4.05  4.38  4.76  5.10  2.34  2.45  2.81  3.05  3.30  3.54  1.56  1.63  1.88  2.03  2.20  2.36
AA/AN/AAC/ANC/AFA  1-1/2  4.81  5.05  5.80  6.28  6.81  7.30  3.36  3.53  4.05  4.38  4.76  5.10  2.23  2.34  2.69  2.91  3.15  3.38
AA/AN/AAC/ANC/AFA  2  7.12  7.46  8.57  9.28  10.06  10.79  4.96  5.20  5.97  6.46  7.01  7.52  3.29  3.45  3.96  4.29  4.66  4.99
AA/AN/AAC/ANC/AFA  3  9.98  10.47  12.02  13.02  14.12  15.14  6.94  7.28  8.35  9.05  9.81  10.52  4.60  4.83  5.54  6.00  6.51  6.98
AA/AN/AAC/ANC/AFA  4  12.25  12.85  14.75  15.97  17.32  18.58  8.50  8.91  10.23  11.08  12.02  12.88  5.66  5.94  6.82  7.38  8.01  8.59
AA/AN/AAC/ANC  5  14.51  15.22  17.48  18.92  20.53  22.01  10.09  10.58  12.15  13.15  14.27  15.30  6.69  7.02  8.06  8.72  9.46 10.15
These factors include corrections for liquid refrigerant density and net refrigerating effect and are based on an average evaporator temperature of 0°F.
However, they may be used for any evaporator temperature from ‑40°F to +40°F since the variation in the actual factors across this range is insignicant.
Refrigerant Liquid Temperature Correction Factors
                   Refrigerant Liquid Temperature °F
      0  10 20 30  40 50  60 70  80 90 100 110 120 130 140
  R-12 Correction Factor     1.60  1.54 1.48 1.42 1.36 1.30  1.24 1.18  1.12 1.06 1.00  .94  .88  .82  .75
  R-134a Correction Factor     1.70  1.63 1.56 1.49 1.42 1.36  1.29 1.21  1.14 1.07 1.00  .93  .85  .78  .71
  R-22 Correction Factor     1.56  1.51 1.45 1.40 1.34 1.29  1.23 1.17  1.12 1.06 1.00  .94  .88  .82  .76
  R-404A/R-507 Correction     2.00  1.90 1.80 1.70 1.60 1.50  1.40 1.30  1.20  1.10 1.00  .90  .80  .70  .50