Brochure

Emerson Climate Technologies
236
System Protectors
Universal replacement cores and lter cores for use in our
ADKS and STAS shells and similar competitive Take-Apart
type lter drier shells. May not be used for BTAS.
Features
Water capacities to suit specic system conditions
Exceptional acid capacities for normal system
protection, or to effectively clean-up following a
compressor burnout
Activated carbon blend for soluble contaminant and
wax removal (W-HH Series)
Nomenclature example: H 48
H 48
Series Cubic Inch
Dimensional Data
Specifications
Interchangeable with competitive products
NOTE: Filter Drier cores are suitable for use with R-11 AND R-123
but lters are NOT.
1
Water Capacities are based on:
2
20 drops of water = 1 gram = 1 cc
Equilibrium Point Dryness (EPD) of:
50 parts per million for R-134a, R404-A/R-410A and R-407C
60 parts per million for R-22
15 parts per million for R-12
3
D-42, H-42 and W-42 include one neoprene composite lid gasket and one core
gasket. All other cores include a universal neoprene composite gasket kit which
includes 2 sizes of replacement lid gaskets, and gaskets for the top and bottom
of the core or lter.
Ordering Information and Capacity Tables
PCN Description
3
Recommended
Refrigerant Type
Function R-134a R-22 R-407C R-404A/R-507 R-410A
75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F
061617 UK-48 CFC, HCFC, HFC Premium Universal Replacement 1272 1168 1181 1072 1033 786 1319 1241 976 707
059541 D-48 CFC, HCFC High Acid Removal 415 340 363 254 225 95 457 343 210 86
059542 H-48 CFC, HCFC High Acid and Water Removal 676 538 597 436 445 285 721 535 380 226
061235 W-48-HH CFC, HCFC, HFC Burnout Cleanup 387 294 335 226 290 165 417 289 249 130
089338 H-100 CFC, HCFC High Acid and Water Removal 1112 834 962 673 726 418 1199 839 672 364
062549 HX-48 CFC, HCFC, HFC Highest Water Removal 1710 1600 1600 1491 1459 1161 1765 1710 1280 930
062424 UK-100 CFC, HCFC, HFC Premium Universal Replacement 2769 2550 2574 2345 2182 1682 2868 2710 - -
043582 W-100-HH CFC, HCFC, HFC Burnout Cleanup 1077 812 938 621 629 363 1162 792 573 307
089559 F-48 CFC, HCFC, HFC Filter (Suction Only)
N/A047664 F-48R CFC, HCFC, HFC
Filter (Suction Only) Reverse
Flow
095762 F-100 CFC, HCFC, HFC Filter (Suction Only)
061237 RH-48 CFC, HCFC Removal 1096 920 1037 790 750 530 1090 940 650 420
061238 RW-48 CFC, HCFC Cleanup 583 493 532 380 380 230 600 482 350 197
Filter Drier
Block Size
Dimensions
Weight
(lbs)
A B C
42 6.00 1.58 3.12 1.00
48 5.50 1.77 3.72 1.50
100 6.50 2.06 4.81 4.00
Catalog
Number
Dimensions
Weight
(lbs)
A B C
F-48/F-48R 5.50 2.81 3.88 0.75
F-100 6.50 3.75 4.81 1.50
Filter Drier Cores and Filters