Brochure
Emerson Climate Technologies
211
Solenoid Valves & Coils
ASC2 – DIN MMG
Voltage/Frequency Description PCN Description PCN
24V50/60Hz ASC2 24/50-60 062792 -- --
24V50/60Hz ASC2L 24/50-60 063542 -- --
120V50/60Hz ASC2 120/50-60 062462 -- --
120V50/60Hz ASC2 GS-2562-1 015384 -- --
208-220/208-24050-60Hz ASC2 208-240/50-60 062463 -- --
208-220/208-24050-60Hz ASC2 GS-2562-2 015383 -- --
12V -- -- MMG 12V DC 063524
12V -- -- MMF 12V DC 062972
24V ASC2 24V DC 064375 MMG 24V DC 063526
AM and ASC 2 style DC coils should not
be used for direct replacements on OEM
equipment. The use of this coil on new
applications may result in the valve not
opening. New applications should use the
MMcoilbecauseofthesignicantincrease
in opening power of the MM Coil over the
standard AM and ASC 2 style DC coil.
Coil Enclosure Options
Options Code
Junction Box G
Conduit - 18” Leads C
Open Frame - 18”
Leads
F
Open Frame - Spades S
Dual Voltage Wiring Diagram
A B
120 240
240 480
RMF
Coils for Solenoid Valves