Brochure
Emerson Climate Technologies
187
EX Extended Capacity Tables
R-410A Extended Capacities (kWatts) EX 5-8 Series,
Application Hot Gas Flow such as Heat Reclaim Application
Valve Type
Condensing
Temperature
°C
Pressure
Drop
bar
Evaporating Temperature (°C)
+15 +10 +5 0 -5 -10 -15 -20 -25 -30 -35 -40 -45
EX6
+60
0.1
6 6 6 6 5 5 5 5 5 5 4 4 4
EX7
21 21 20 20 19 19 18 18 17 16 16 15 15
EX8
64 63 62 60 58 57 55 53 52 50 48 46 44
EX6
0.5
13 13 13 12 12 12 11 11 11 10 10 10 9
EX7
47 46 45 44 43 41 40 39 38 36 35 34 32
EX8
143 140 137 133 130 126 122 118 115 111 107 103 99
EX6
1.0
19 18 18 17 17 16 16 15 15 14 14 13 13
EX7
66 64 63 61 60 58 56 55 53 51 49 47 46
EX8
200 196 191 186 182 177 171 166 161 155 150 144 138
EX6
+50
0.1
6 6 6 6 6 6 5 5 5 5 5 5 4
EX7
22 22 21 21 20 20 19 19 18 18 17 17 16
EX8
67 66 65 63 62 60 59 57 55 54 52 50 48
EX6
0.5
14 14 13 13 13 12 12 12 11 11 11 10 10
EX7
49 48 47 46 45 44 43 42 40 39 38 37 35
EX8
149 146 143 140 137 133 130 126 123 119 115 111 108
EX6
1.0
19 19 19 18 18 17 17 16 16 15 15 14 14
EX7
69 67 66 64 63 61 60 58 57 55 53 51 50
EX8
209 204 200 196 191 186 182 177 172 167 161 156 151
EX6
+40
0.1
6 6 6 6 6 6 5 5 5 5 5 5 5
EX7
22 22 21 21 20 20 19 19 18 18 17 17 16
EX8
67 66 65 63 62 60 59 58 56 54 53 51 50
EX6
0.5
14 13 13 13 13 12 12 12 11 11 11 11 10
EX7
49 48 47 46 45 44 43 42 41 40 39 37 36
EX8
148 146 143 140 137 134 131 127 124 121 117 114 110
EX6
1.0
19 19 18 18 18 17 17 16 16 16 15 15 14
EX7
68 67 66 64 63 61 60 59 57 55 54 52 51
EX8
207 203 199 195 191 187 182 178 173 168 164 159 154
EX6
+30
0.1
6 6 6 6 6 5 5 5 5 5 5 5 5
EX7
21 21 21 20 20 19 19 19 18 18 17 17 16
EX8
65 64 63 61 60 59 58 56 55 53 52 51 49
EX6
0.5
13 13 13 13 12 12 12 12 11 11 11 10 10
EX7
47 46 45 45 44 43 42 41 40 39 38 37 36
EX8
143 141 138 135 133 130 127 124 121 118 115 112 109
EX6
1.0
18 18 18 17 17 17 16 16 16 15 15 14 14
EX7
65 64 63 62 61 60 58 57 56 54 53 51 50
EX8
199 195 192 188 185 181 177 173 169 165 160 156 152