6.0 Power Requirements
Jacuzzi
®
spas are designed to provide optimum performance and
exibility of use when connected to their maximum electrical service.
They are congured at the factory. The most common electrical
connections are listed below:
All North American 60 Hz Models: 240VAC/50A**
All Export 50 Hz Models: 240VAC/30A**
If you prefer, your qualied technician can perform a minor circuit board
modication that allows the spas to operate on a different electrical
service (see table footnotes below).
North American J-460/J-465/J-470/J-480 Models (60 Hz)
Voltage: 240VAC 240VAC 240VAC
Max. Current Draw: 23A 36A 45A
Frequency: 60 Hz 60 Hz 60 Hz
Number of Wires: 3 3 3
Circuit Breaker (2-Pole): 30A* 50A** 60A***
*
In 30A conguration, the heater will not operate while either jets
pump is running.
**
In 50A conguration, the heater will not operate while both jets
pumps are running. This is the factory setting.
***
In 60A conguration the heater will operate while both jets pumps
are running.
Export J-460/J-465/J-470/J-480 Models (50 Hz)
Voltage: 240VAC 240VAC 240VAC
Max. Current Draw: 16A 21A 29A
Frequency: 50 Hz 50 Hz 50 Hz
Number of Wires: 3 3 3
Circuit Breaker (2-Pole): 20A* 30A** 40A***
*
In 20A conguration, the heater will not operate while either jets
pump is running.
**
In 30A conguration, the heater will not operate while both jets
pumps are running. This is the factory setting.
***
In 40A conguration the heater will operate while both jets pumps
are running.