TROUBLESHOOTING cont... 
A hardware error was detected in in.xm.
• Restart the spa pack and start and stop all 
 pumps and blower.
• If error reappears, contact local dealer to   
 schedule a service call.
User tried to set input current rating lower 
than the sum of current for all pumps.
• Increase in.xm current rating (and breaker) or 
 reduce pump size.
Input voltage is too low. 
Either there is a problem with the terminal 
connections or with the power line.
• Check input terminal connections to make  
 sure they are correctly wired and tightened.
• Have a certied electrician verify the quality of 
 the power line.
An in.xm fuse is blown.
Fan, blower, ozone, circulation pump, 
ber optic.
• Replace the blown fuse with an identically 
rated replacement (SC-20, SC-25, etc.).
An in.xm fuse is blown.
Pump 2 and Pump 3, or a blower that is more 
than 5 amps.
• Replace the blown fuse with an identically 
rated replacement (SC-20, SC-25, etc.).
An in.xm fuse is blown.
Pump 2 and Pump 3, or a blower that is more 
than 5 amps.
• Replace the blown fuse with an identically 
rated replacement (SC-20, SC-25, etc.).