Product specifications

SecurStor 16i Installation and Hardware Reference Manual
1-10
Figure 1-10: Cooling Module
1.3 Subsystem Monitoring
The iSCSI RAID subsystem comes with a number of different monitoring methods
that provide you with continual updates on the operating statuses of the subsystem
and individual components. The following monitoring features are included:
1.3.1 I
2
C bus
The following subsystem elements are interfaced to the RAID controller
over a non-user-serviceable I
2
C bus:
Cooling modules
Module presence detection circuits
Temperature sensors (for detecting the temperature of the
backplane board and controller board)
1.3.2 LED Indicators
The following components come with LEDs to indicate the operating
statuses of individual components:
RAID controller
BBU module
Cooling modules (on PSU faceplates)
PSU modules (1 LED on each module)
Drive trays (2 LEDs on each tray)