User manual

Locating Beeper Operating Instructions Version 1.0
Page 7 of 20
3. Functionality
There are several options for activating the alarm:
A defined servo position, e.g. by a switching channel of the
transmitter (servo position < -100%)
The defined servo position of a servo which is connected in
parallel to the Locating Beeper (e.g. choke servo or tow
release)
Failsafe setting of the servo position (e.g. turning the
transmitter off)
Missing or erroneous servo signal (e.g. turning the transmitter
off)
Suddenly missing external supply (PRO-version only)
The receiver does not deliver a servo signal (PPM modulation) if the
pilot turns the transmitter off. This is recognized by the Locating
Beeper which then will signal alarm.