User manual
DPSI RV Family Operating Instructions Version 2.1
page 23 of 44
Gas Cap Switch Actuator (magnetically):
Alternatively a gas cap switch actuator is available. The design mimics
a gas cap. Here too, switch is done with a magnet. Pulling it off turns
on, plugging in turns off.
6.4. Connecting the Receiver
Connect the receiver with provided patch-cables to the DPSI (see print
on housing). Not all inputs must be used when connecting the receiver.
Only connect that many patch-cables as required. Each patch-cable
supplies the receiver power.
Hint:
All receiver connector cables supply the receiver with the regulated output
voltage! Hence it is does not matter which cable (which channel) is connected.