User manual

Slave Components - G-Modules (General Purpose)
Product Catalogue all information for reference only - technical changes reserved - rev. 9 Page 69 of 171
Analog Input x
-
-
-
-
-
-
AIV9
AIV8
Bit 15
Bit 8
AIV7
AIV6
AIV5
AIV4
AIV3
AIV2
AIV1
AIV0
Bit 7
Bit 0
Bit 9-0 ......................................... AIV<9:0>: Analog Input Value (Little Endian)
11 1111 1111 = Analog Input Value: 1023
00 0000 0000 = Analog Input Value: 0
Pulse Input Sum x
TR1
TR0
PISV13
PISV12
PISV11
PISV10
PISV9
PISV8
Bit 15
Bit 8
PISV7
PISV6
PISV5
PISV4
PISV3
PISV2
PISV1
PISV0
Bit 7
Bit 0
Bit 15-14 .................................... TR<1:0>: Time Reference; 2 Bit Counter that counts up every
millisecond. Can be used to compensate the clock deviation of
the emBRICK®-module.
Bit 13-0 ....................................... Pulse Input Sum Value; Increments on falling edge; Resets to
zero on overflow (Little Endian):
11 1111 1111 1111 = 16383
00 0000 0000 0000 = 0
Pulse Input Difference x
PIDV15
PIDV14
PIDV13
PIDV12
PIDV11
PIDV10
PIDV9
PIDV8
Bit 15
Bit 8
PIDV7
PIDV6
PIDV5
PIDV4
PIDV3
PIDV2
PIDV1
PIDV0
Bit 7
Bit 0
Bit 15-0 ....................................... PIDV<15:0>: Pulse Input Difference Value
in Mode “Fixed Gate Time”:
Displays all fallen edges monitored in the timeframe defined in
Pulse Input Attribute x
6.2.7.8 Programming Note
In addition to the notes in chapter 4, please regard the following: