User manual

Slave Components - G-Modules (General Purpose)
Product Catalogue all information for reference only - technical changes reserved - rev. 9 Page 68 of 171
Pulse Input Control x
MODE5
MODE4
MODE3
MODE2
MODE1
MODE0
MSET9
MSET8
Bit 15
Bit 8
MSET7
MSET6
MSET5
MSET4
MSET3
MSET2
MSET1
MSET0
Bit 7
Bit 0
Bit 15-10 .................................... MODE<4:0>: Pulse Input operating Mode
110010 = Mode Period Duration with Time Grid 50ms
110001 = Mode Period Duration with Time Grid 49ms
000010 = Mode Period Duration with Time Grid 2ms
000001 = Mode Period Duration with Time Grid 1ms
000000 = Mode Fixed Gate Time
Bit 9-0 ......................................... MSET<9:0>: Mode Settings
in Mode “Period Duration”: Filter Period in ms, to filter out con-
tact chattering (Little Endian):
11 1111 1111 = Filter Period 1023ms
00 0000 0000 = Filter Period 0ms
in Mode “Fixed Gate Time”:
Mode Settings has no effect
Pulse Input Attribute x
ATTR15
ATTR14
ATTR13
ATTR12
ATTR11
ATTR10
ATTR9
ATTR8
Bit 15
Bit 8
ATTR7
ATTR6
ATTR5
ATTR4
ATTR3
ATTR2
ATTR1
ATTR0
Bit 7
Bit 0
Bit 15-0: ...................................... ATTR<15:0>: Additional Pulse Input Attributes
in Mode “Period Duration”: Timeout for 0-setting (Little Endian):
1111 1111 1111 1111 = 65535 * Time Grid
0000 0000 0000 0000 = 0
in Mode “Fixed Gate Time”: Gate Time in ms (Little Endian):
1111 1111 1111 1111 = 65535ms
0000 0000 0000 0000 = 0ms