Instructions / Assembly
www.sureheat.com
19200084-01A
INSPECTING BURNERS
IMPORTANT: Owner’s should check pilot ame pattern and burner ame pattern often.
Incorrect ame patterns indicate the need for cleaning (see Care and Maintenance,
page 20) or service.
WARNING: Only a qualied service person should service and
repair heater. This includes maintenance requiring replacement or
alteration of components.
PILOT FLAME PATTERN
Figure 22, page 20, shows a correct pilot
ame pattern. Figure 23, page 20, shows an
incorrect pilot ame pattern. The incorrect pilot
ame is not touching the thermocouple. This
will cause the thermocouple to cool, which
shuts the heater off.
If pilot ame pattern is incorrect, as shown in
Figure 23, page 20
• turn heater off (see To Turn Off Gas to Ap-
pliance)
• see Troubleshooting pages 22 through 24.
WARNING: If yellow tipping
occurs, the pilot should be
cleaned.
Notice: Do not mistake orange ames with
yellow tipping. Dirt or other ne particles enter
the heater and burn causing brief patches of
orange ame.
OPERATION
Shutting Off Heater
Turn control knob clockwise to the
OFF position.
Shutting Off Burner Only (pilot
stays lit )
Turn control knob clockwise to the
PILOT position.
1. Remove screen by lifting and pulling
forward.
2. Follow steps 1 through 5 under Lighting
Instructions, page 18.
3. With control knob in PILOT position, strike
match, and hold near pilot. Press in control
knob; pilot should light.
4. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
5. Make sure the heater screen is in place
before operating heater.
THERMOSTAT CONTROL OPERATION
The thermostatic control used on this model
differs from standard thermostats. You set
standard thermostats to a specic tempera-
ture such as 72 degrees. The thermostat
used on this heater senses the room tem-
perature. At times the room may exceed the
set temperature. If so, the burner will shut
off. The burner will cycle back on when room
temperature drops below the set temperature.
The control knob can be set to any comfort
level between HIGH (5) and LOW (1).
Note: The thermostat sensing bulb reacts
to the temperature depending on housing
construction.
TO TURN OFF GAS TO APPLIANCE
MANUAL LIGHTING PROCEDURE