Instructions / Assembly
www.sureheat.com
11200084-01A
INSTALLATION
Figure 9 - Rough Opening for Wall
Installation
Figure 7 - Clearance to Combustibles
Figure 8 - Fireplace Clearances
3/4" Clearance to Facia
Note: Height of fireplace opening on facia to be 23
1
/
4
"
1
3
/
8
" Clearance to Sides, Back and Top
27
3
/
4
"
28
3
/
4
"
13"
16"
19"
21"
10"
8"
6"
2
1
/
2
"
Side of
Firebox
Mantel
Shelf
Note: All vertical
measurements
are from top of
fireplace
opening to
bottom of
mantel shelf. All
measurements
are in inches.
23.25"
12.75"
28.75"
1. Frame in rough opening. Use dimensions
shown in Figure 9 for the rough opening.
If installing in a corner, use dimensions
shown in Figure 10 for the rough opening.
The height is 26
1
/
2
", which is the same as
the wall opening above.
2. Carefully set replace in front of rough
opening with back of replace inside wall
opening.
3. Attach gas line to replace gas regulator.
See Connecting to Gas Supply, page 13.
4. Check all gas connections for leaks. See
Checking Gas Connections, page 15.
Figure 10 - Rough Opening for Corner
Installation
37.4"
28.75"
53.8"
26.5"
IMPORTANT: When nishing your rebox,
combustible materials such as wall board,
gypsum board, sheet rock, drywall, plywood,
etc, must have 1/2" clearance to the sides
and top of the rebox. Combustible materials
should never overlap the rebox front.