Full Product Manual

www.sureheat.com
13200208-01C
INSTALLATION
DO NOT use an off the shelf 3/8"
NPT pipe plug. This will damage
the plungers located inside the
regulator.
DO NOT try to remove the plung-
ers from inside the regulator. The
plunger will be pushed back as
the tting is installed.
Make sure the type of gas being
used is correct. Check to make
sure the connection tting is in
the correct inlet on the regula-
tor. Refer to Connecting to Gas
Supply, page 15.
If you are using natural gas
and the pilot will not light, see
Troubleshooting, page 24.
Use only the cap supplied on the
regulator. Do not use an off the
shelf pipe plug. This can damage
the plunger. The supplied regula-
tor cap is designed so it will not
engage the unused gas type.
4. Apply thread sealant to the threads on
the connection fitting (supplied by in-
staller). While pushing in, rotate the tting
clockwise until the threads engage the
regulator. After the tting has been hand
tightened into the regulator use a wrench
to complete tightening of the tting. Install
additional tting to connect to the house
supply.
Metal
Cap
Fitting
supplied
by installer,
may vary.
Metal Cap
DO NOT REMOVE
Yellow Natural Gas Plunger
Install Gas Fitting Here
2. Apply thread sealant to the threads on
the connection fitting (supplied by in-
staller). While pushing in, rotate the tting
clockwise until the threads engage the
regulator. After the tting has been hand
tightened into the regulator use a wrench
to complete tightening of the tting. Install
additional tting to connect to the house
supply.
FOR NATURAL GAS (NG)
INSTALLATION: YELLOW
1. Remove the blue dust cover from the
regulator.
2. Remove the metal cap installed over the
NG regulator inlet.
3. Install metal cap over LP/Propane regulator
inlet. This will keep debris out of regulator.