Installation Guide
For natural gas, check gas line pressure
before connecting heater to gas line. Gas line pressure must
be no greater than 10.5” of water. If gas line pressure is
higher, heater regulator damage could occur.
For propane/LP gas, the installer must supply an external
regulator. The external regulator will reduce incoming gas
pressure. You must reduce incoming gas pressure to between
11” and 14” of water. If you do not reduce incoming gas
pressure, heater regulator damage could occur. Install the
external regulator with the vent pointing down as shown in
Figure 12. Pointing the vent down protects it from freezing
rain or sleet.
Mantel Clearances for Installation
If placing mantel above heater, you must meet the mini-
mum clearance between the mantel shelf and the top of