Full Product Manual

LOG PLACEMENT
MODEL: SH24NG Continued
Place cross-log (7) atop cross-log (6) and
to front center a s shown
15
MAINTENANCE
Very little maintenance is required. The carbon deposit resulting from combustion is natural and adds to the
realistic appearance of the set. If carbon becomes excessive it can be lightly brushed or vacuumed away.
TROUBLE SHOOTING
Problem Cause Corrective Action
1. No Ignition -Valve not fully in “on” position -turn valve to “on” position
-gas line obstruction -inspect supply lines/ tube for
kinks or obstructions
2. Inadequate ame -Valve partially closed -open valve fully
-gas line partial obstruction -inspect burner tube for kinks
or obstructions
-log arrangement incorrect -rearrange logs to specified pattern
We recommend for the appliance and the fireplace flue to be professionally inspected and cleaned each year,
prior to operation.
Figure 11 - Incorrect Burner Flame Pattern
Figure 10 - Correct Burner Flame Pattern
Each time you operate the gas log set, pay attention to the flame pattern, and the amount of carbon (soot)
being produced. If the gas log set continuously produces excessive carbon, you may wish to rearrange the
stack of the logs to allow more free space for the flames.
VISUAL INSPECTION AND MONITORING OPERATION
(Excessive flame height, combined
with extremely yellow flames prod-
ucing carbon (soot)).