Tested & Listed By C US Z21.
Safety ............................................................... 2-3 Product Identification ........................................... 3 Local Codes .........................................................4 Unpacking ............................................................4 Product Features ................................................. 4 Installation ............................ ........................ 4-16 .............. 17 Operation .. ......................................................
SAFETY Continued 4. You must operate this log set with fireplace screens in place and fully closed. Unless provided by other means, fireplace doors or screens shall haveopenings for introduction of combustion air. 10. Do not run log set: • where combustible materials, gasoline and other flammable vapors and liquids are used or stored • under dusty conditions 5. This log set is designed to be smokeless. If logs ever appear to smoke, turn off appliance and call a qualified service person.
UNPACKING LOCAL CODES Install and use log set with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSIZ223.1/NFPA 54*. . *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269 CAUTION: Do not remove the metal data plates from the burner pan. The data plates contain important warranty and safety information. 1.
INSTALLATION Continued The charts in Figure 2 indicate technical information regarding the installation of your gas log set. Please make sure that all of the specifications shown are applicable before installation is attempted. The fireplace must include a working flue and venting system with the minimum openings shown in the Figure 2. LOG SIZE 24" MINIMUM FIREBOX SIZE FRONT BACK MINIMUM WIDTH WIDTH* DEPTH HEIGHT FLUE SIZE 8" dia. 35 3/4" 17" 15 1/2" 18" CHECK GAS TYPE Use only natural gas.
INSTALLATION Continued We recommend that you install a sediment trap in the supply line as shown in Figure 4. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into log set controls. If sediment trap is not installed or is installed wrong, log set may not run properly.
INSTALLATION Continued 5. Retighten and adjust the location of the gas control as necessary. The gas control should be level, with the control knob to the front. Be sure to use the correct orifice for your appliance. The orifice kit included with this appliance contains an orifice installed in an air mixer fitting. 4. Using thread sealant (resistant to the action of propane/LP gas) on smaller end of fitting, screw the burner inlet fitting into outlet side of gas control. Tighten using a wrench. 5 .
INSTALLATION Continued 5. Turn pressure selecting screw over and reinstall it in regulator cap (see Figure 10-11).This will set the pressure selecting screw to the LP/Propane gas position. Make sure the pressure selecting screw is installed tightly to the regulator cap. 6. Replace the regulator cap on the appliance regulator.
LOG PLACEMENT VMO24RNGA 1 8 2 9 10 4 6 7 3 5 Log Identification Back Log Stand-Offs in place 2 1 Place main front log (1) onto front area of the grate Place shorter back log (2) onto raised area of the grate 4 3 Place Cross-Log (3) at the left side Place Cross-Log (4) at the center right 5 6 Place Cross-Log (5) atop (3) and (4) at the back left Place Cross-Log (6) atop (3) and (1) on the left side front.
LOG PLACEMENT VMO24RNGA Continued 7 Place Cross-Log (7) at the top back, on the right side 9 8 Place Cross-Log (8) atop (1) and (7) at the center right 10 Place smallest decorative logs (9) and (10) onto the fireplace floor at each end of burner pan WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
LOG PLACEMENT MODEL MO24DBRNL-60 5 6 4 3 2 1 Log Identification MO18NG Back Log Stand-Offs in place Place Main Front Log (1) onto front area of the grate Place shorter back log (2) onto Back Log Stand-Offs Place Cross-Log (3) at the left side Place Cross-Log (4) at the center Place Cross-Log (5) at the right side Place Cross-Log (6) from the center to the right side 11
LOG PLACEMENT MODEL: BRO24DBRNL-60 8 9 7 3 4 6 1 2 5 Log Identification Place log (1) onto back right area of the grate 12 Back Log Stand-Offs in place Place “Y” shaped log (2) onto left of the grate ahead of raised area Place log (3) onto back left area of the grate, perpendicular to log (1) Place log (4) at the front right of the grate with the “split” area to the flame Place log (5) on to log (2) and brace it on the grate finger left of center Place log (6) atop logs (5) and (4) as shown
LOG PLACEMENT MODEL: SH24DBRNL-60 7 5 2 4 1 3 6 Log Identification Place main front log (1) onto front area of the grate Back Log Stand-Offs in place Place shorter back log (2) onto raised area of the grate Place Cross-Log (3) at the left side Place Cross-Log (4) at the center left Place Cross-Log (5) at the center right Place Cross-Log (6) at the right side 13
LOG PLACEMENT MODEL: SH24DBRNL-60 cont.
LOG PLACEMENT MODEL CS30DBRNL-60 7 9 3 8 2 5 1 6 4 Log Identification Place Right front log (1) onto front area of the grate Place back log (3) onto raised area of the grate Place “Y” shaped Cross-Log (5) at right Back Log Stand-Offs in place Place left front log (2) onto front area of the grate Place Cross-Log (4) at the center left Place Cross-Log (6) from front left to lay on log (5) as shown 15
LOG PLACEMENT MODEL: CS30DBRNL-60 Cont.
OPERATION FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: Keep flue open when operating unit. WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas.
LIGHTING INSTRUCTION Continued 9. Slightly push in and turn control- knob counterclockwise to the ON position. 10.To leave pilot lit and shut off burners only: to the PILOT Turn control knob clockwise position, or set selector switch in the OFF position. TO TURN OFF GAS TO APPLIANCE Shutting Off Appliance 1. Slightly push in and turn control knob clockwise to the OFF position. 2. Close equipment shutoff valve.
CLEANING AND MAINTENANCE • Keep the area around the log set clean and clear of debris. • Occasionally, you may use a soft bristle brush to clean logs. • Periodically inspect the air mixer and burner tube for foreign matter blocking the air inlet and flame holes. • Once every year a qualified agency or certified chimney sweep should examine and clean the venting system of the fireplace.
TROUBLESHOOTING OBSERVED PROBLEM Continued POSSIBLE CAUSE REMEDY Delayed ignition burner. 1. Pilot flame needs adjust ing. 2. W rong pilot orifice for gas type. 1. Adjust pilot flame for approximately 2" blue flame. 2. Replace pilot orifice. Remote does not function. Battery is not installed. Battery power may be low . 1. Incorrect gas supply or pressure. Replace batteries in receiver and/or remote control. 1. Check for proper gas supply pressure. 2.
DB24/30RNL-60 and VMO24RNGA PARTS 22 21 24 2 19 23 18 20 19 7 1 27 6 28 5 4 16 LP Conversion 3 L 8 15 17 9 25 14 11 13 12 10 26 28 21`
DB24/30RNL-60 PARTS Continued KEY NO. DESCRIPTION DB24 . DB30 1 SBNCJ00365A Burner Pan, 24” Sets SBNCJ00366A Burner Pan, 30” Sets RCOCB00002A Burner Tube, 24” Sets RCOCB00003A Burner Tube, 30” Sets 3. RMH-120-00085B Orifice Holder, Natural Gas 1 1 4. RMH-120-90955 Orifice, Natural Gas 1 1 5. RMH-120-00084B Orifice, Propane/LP Gas 1 1 6. RMH-120-00324 Orifice, Propane/LP Gas 1 1 7. RCODZ00145A Washer 1 1 8. RMH-120-00574 Pal Nut 1 1 9.
NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ __________
LIMITED WARRANTY Sure Heat Mfg. warran ts that the components of this appliance are warranted free from defects in material and workmanship for one (1) year from the date of purchase. Sure Heat Mfg.at its option, willrepair or replace this product or any component of the product found to be defective during the warranty period. Replacement willbe made with a new manufactured product or component. If the product is no longer available, replacement may be made with a similar product of equal value.