Product data

96
M-Module Mezzanine I/O
MEN M-Module Mezzanine I/O
M68 – Quad Output Function & Waveform Generator
4 16-bit D/A converters
Individual offset and output voltage range
100kHz update rate per channel
7µs acquisition/conversion time
±10V measuring range
2 DSPs, 32 MIPS each
160kB memory
Optical isolation
D/A Conversion
Resolution: 16 bits
Conversion time: 7µs
Absolute accuracy: ±0.5%
Differential accuracy: ±0.05%,
no missing codes
Outputs
4 analog outputs
Current range: ±1mA
Voltage range: ±10V
Output accuracy depends on load resistance
Output impedance: 0 Ohm
Miscellaneous
Adjustable peak via 12-bit DAC
Self-calibration (firmware)
6th-order output lowpass filter 15kHz
100kHz maximum output rate
Digital Signal Processing
2 processors ADSP 2181 (Analog Devices)
Data reduction by interpolation
16k x 16 bits data buffer
16k x 24 bits program memory
Programming via host interface
External or internal trigger
(software-programmable)
Peripheral Connections
Via front panel on 4 shielded receptacle
connectors
Via carrier board (rear I/O)
M-Module Characteristics
A08, D16, INTA, IDENT, TRIGI
Electrical Specifications
Isolation voltage:
500V DC between isolated and digital side
Voltage between the connector shield and
isolated ground is limited to 180V using a
varistor; AC coupling between connector
shield and isolated ground through
47nF capacitor
Supply voltage/power consumption:
+5V (4.85V..5.25V), 500mA
MTBF: 151,000h @ 50°C
Mechanical Specifications
Dimensions: conforming to
M-Module Standard
Weight: 98g
Environmental Specifications
Temperature range (operation):
0..+60°C or -40..+85°C
Airflow: min. 10m
3
/h
Temperature range (storage): -40..+85°C
Relative humidity range (operation):
max. 95% non-condensing
Relative humidity range (storage):
max. 95% non-condensing
Altitude: -300m to + 3,000m
Shock: 15g/0.33ms, 6g/6ms
Vibration: 1g/5..2,000Hz
Safety
PCB manufactured with a flammability rating
of 94V-0 by UL recognized manufacturers
EMC
Tested according to EN 55022 / 1999-05
(radio disturbance) and EN 55024 / 1999-05
(immunity) with regard to CE conformity
Software Support
MEN Driver Interface System
(MDIS for Windows, Linux, VxWorks, QNX,
RTX, OS-9)
Standard firmware
Host Toolbox (C library)