M-Module Mezzanine I/O
MEN M-Module Mezzanine I/O
M76 – Digital Multimeter
Resolution
22.5 bits @ 10Hz sampling
20 bits @ 50/60 Hz sampling
11 bits @ 1kHz sampling
DC Voltage Measurement
Maximum input voltage if no further safety
measures are taken:
60V DC / 42V AC for all measuring ranges
Maximum input voltage if requirements
of EN60950 are fulfilled through additional
safety measures (see user manual):
High-voltage input: 500V DC for 500V range
Normal input: 125V DC for 125mV, 1.25V,
12.5V and 125V range
Measuring ranges:
-125mV..+125mV, -1.25V..+1.25V,
-12.5V..+12.5V, -125V..+125V, -500V..+500V
Measuring accuracy:
24 hours, 23°C ±1°C: error < 0.025%
90 days, 23°C ±5°C: error < 0.05%
Temp. coefficient 0°C..+55°C: error < 0.01%
Input impedance:
40 MOhm @ 500V input (HV)
10 MOhm @ 125V and 12.5V range
> 1 GOhm @ 1.25V and 125mV range
Input current: max. 10pA @ 23°C
CMRR: 100dB @ 50/60Hz
NMRR: 60dB @ 50/60Hz
AC Voltage Measurement
Maximum input voltage if no further safety
measures are taken: 60V DC / 42V AC
for all measuring ranges
Maximum input voltage if requirements of
EN60950 are fulfilled through additional
safety measures (see user manual):
High-voltage input: 250V AC
Normal input: 60V AC
Measuring ranges:
250mV RMS, sine 40Hz..100kHz, error < 5%
2.5V RMS, sine 40Hz..100kHz, error < 1%
25V RMS, sine 40Hz..100kHz, error < 1%
250V RMS (high-voltage input),
sine 40Hz..100Hz, error < 1%
Crest factor: max. 4
Measuring accuracy @ 50/60Hz:
24 hours, 23°C ±1°C: error < 0.5%
90 days, 23°C ±5°C: error < 1%
Range error < 1%
Input impedance:
High-voltage input: 40 MOhm
Normal input: 1 MOhm
Input current: max. 10pA @ 23°C
CMRR: 100dB @ 50/60Hz
DC Current Measurement
Maximum input voltage if no further safety
measures are taken:
60V DC for all measuring ranges
Measuring ranges:
-12.5mA..+12.5mA, -125mA..+125mA,
-1.25A..+1.25A, -2.5A..+2.5A
Measuring accuracy:
24 hours, 23°C ±1°C: error < 0.025%
90 days, 23°C ±5°C: error < 0.05%
Temp. coefficient 0°C..+55°C: error < 0.01%
Shunt:
1 Ohm @12.5mA, 125mA range
0.1 Ohm @ 1.25A, 2.5A range
AC Current Measurement
Maximum input voltage if no further safety
measures are taken:
42V AC for all measuring ranges
Sine 40Hz..100Hz
Measuring ranges:
25mARMS, 250mARMS, 2.5ARMS
Crest factor: max. 4
Measuring accuracy:
24 hours, 23°C ±1°C: error < 0.5%
90 days, 23°C ±5°C: error < 1%
Range error < 1%
Shunt:
1 Ohm @ 25mA, 250mA range
0.1 Ohm @ 2.5A range
Resistance Measurement
Measuring ranges: 250 Ohm, 2.5 kOhm,
25 kOhm, 250 kOhm, 2.5 MOhm
Measuring accuracy: 250 Ohm, 2.5 kOhm,
25 kOhm, 250 kOhm:
24 hours, 23°C ±1°C: error < 0.1%
90 days, 23°C ±5°C: error < 0.2%
Temp. coefficient 0°C..+55°C: error < 0.01%
Measuring accuracy 2.5 MOhm:
24 hours, 23°C ±1°C: error < 1%
90 days, 23°C ±5°C: error < 2%
Temp. coefficient 0°C..+55°C: error < 0.1%
Measuring modes: 2- and 4-wire
Maximum measuring voltage: 2.5V
Peripheral Connections
Via front panel on a 5-pin 5W5S D-Sub
receptacle connector with high-voltage
contacts (recommended)
Via carrier-board connector (rear-panel I/O)
(not recommended)
M-Module Characteristics
A08, D16, INTA, IDENT
Safety
THE M76 DOES NOT COMPLY WITH THE
REQUIREMENTS OF THE EN60950 STANDARD.
THE MAXIMUM INPUT VOLTAGES FOR ALL TYPES
OF MEASUREMENTS ARE 60V DC AND 42V AC.
HOWEVER, THE M76 WAS DESIGNED TO PROVIDE
HIGH-VOLTAGE FUNCTIONALITY. IF YOU NEED TO
APPLY VOLTAGES HIGHER THAN 60V DC AND
42V AC, TAKE APPROPRIATE MEASURES TO KEEP
THE SAFETY REQUIREMENTS OF EN60950.
PCB manufactured with a flammability rating
of 94V-0 by UL recognized manufacturers
Software Support
MEN Driver Interface System (MDIS for
Windows, Linux,VxWorks, QNX, RTX, OS-9)
Up to 22 bits resolution (6 1/2 digits)
Max. resolution 50nV, 5nA, 50µOhm
52 µs acquisition/conversion time
0.01% DC accuracy
20 measuring ranges
DC: ±125mV..±500V; ±12.5mA..±2.5A
AC: 250mV RMS..250V RMS; 25mA RMS..2.5A RMS
Input voltages over 60V DC and 42V AC only
with appropriate additional safety measures
according to EN60950!
Resistance: 0..2.5 MOhm
True RMS measurements
Autocalibration
Optical isolation