Product data
A/D Conversion
■ 16 bits @ 10µs
■ Precision: ±2 LSB, ±0.1% typ.
■ Noise: ±3 LSB of mean value, delta = 0.8
■ Optically isolated (500V isolation)
■ Programmable gain factor of 1, 2, 4 or 8
(factor 16 by hardware jumpering)
■ Offset max. 4 LSB (25°C)
■ Full-scale error max. 4 LSB (25°C)
■ Software-selectable unipolar or bipolar
operation
■ Sample and hold
■ Autoincrement of channel number
Input Signal Conditioning
with AD01
■ Voltage or Current Inputs
■■ 16 analog inputs, single-ended
■■ High input voltage tolerance
■■ Cross-talk less than 56db
■■ Low-pass filter 1kHz
■ Voltage Measurement
■■ Precision: ±0.5%
■■ Voltage max.: ±15V
■■ Voltage full scale: ±10V
■■ Input resistance: 100 kOhm, ±10%
■ Current Measurement
■■ Precision: ±1%
■■ Current max.: ±25mA
■■ Current full scale: ±20mA, UA = ±1.25V
■■ Load resistance: 62.5 Ohm, ±0.1%
Input Signal Conditioning
with AD02
■ Voltage or Current Inputs
■■ 8 analog inputs, differential
■■ High common mode range ±200V
■■ Cross-talk less than 60db
■■ Low-pass filter 3kHz
■ Voltage Measurement
■■ Precision: ±0.5%
■■ Voltage max.: ±200V (common mode)
■■ Voltage full scale: ±10V
■■ Input resistance: 400 kOhm typ.
■ Current Measurement
■■ Precision: ±1%
■■ Current max.: ±25mA
■■ Voltage max. to IGND: ±200V
■■ Input resistance: 62.5 Ohm, ±0.1%
Miscellaneous
■ External trigger (isolated, rising-edge sensitive)
■ External binary input
Peripheral Connections
■ Via front panel on a shielded 25-pin D-Sub
receptacle connector
■ Via carrier board (rear I/O)
M-Module Characteristics
■ A08, D16, INTA, IDENT
Electrical Specifications
■ Isolation voltage:
■■ 500V DC between isolated and digital side
■■ 180V DC between the channels
■■ Voltage between the connector shield and
isolated ground is limited to 180V using a
varistor; AC coupling between connector
shield and isolated ground through 47nF
capacitor
■ Supply voltages/power consumption:
■■ +5V (4.85V..5.25V), 110mA typ.
(without DC/DC converter), 580mA (with
DC/DC), 990mA (with DC/DC and AD01)
■■ External supply voltages (without on-board
DC/DC converter and adapter): +15V:
14.5V..15.5V, +60mA; -15V:
14.5V..15.5V, -32mA
■ MTBF: 44,000h @ 50°C
Mechanical Specifications
■ Dimensions: conforming to
M-Module Standard
■ Weight (incl. adapter): 102g
Environmental Specifications
■ Temperature range (operation):
■■ 0..+60°C
■■ Industrial temperature range on request
■■ Airflow: min. 10m
3
/h
■ Temperature range (storage): -40..+85°C
■ Relative humidity range (operation):
max. 95% non-condensing
■ Relative humidity range (storage):
max. 95% non-condensing
■ Altitude: -300m to + 3,000m
■ Shock: 15g/0.33ms, 6g/6ms
■ Vibration: 1g/5..2,000Hz
Safety
■ PCB manufactured with a flammability rating
of 94V-0 by UL recognized manufacturers
EMC
■ Tested according to EN 55022 / 1999-05
(radio disturbance) and EN 55024 / 1999-05
(immunity) with regard to CE conformity
Software Support
■ MEN Driver Interface System
(MDIS for Windows, Linux, VxWorks, QNX,
RTX, OS-9)
80
M-Module Mezzanine I/O
MEN M-Module Mezzanine I/O
M36 – 8/16 Analog Inputs
■ 8/16 current or voltage inputs
■ 16 bits resolution
■ 10 µs acquisition/conversion time
■ Unipolar/bipolar software-selectable
■ Auto-sampling system
■ Communication via dual-ported RAM
■ External triggering
■ Optical isolation
■ On-board signal conditioning via separate adapter