M-Module Mezzanine I/O
MEN M-Module Mezzanine I/O
■ 4 current or voltage outputs
■ 16 bits high resolution
■ 8.5 µs acquisition/conversion time
■ Simultaneous channel update
■ Synchronization with external trigger
■ Optical isolation
M37 – 4 Analog Outputs
D/A Conversion
■ 4 channels
■ 16 bits
■ Conversion time: 8.5µs
■ Output linearity: ±1LSB
■ Simultaneous updating of all channels
■ Synchronization with external trigger
Voltage Output
■ Output current: ±5mA max.
■ Accuracy: ±0.3%
■ Voltage range: -10V..+10V
Current Output
■ Accuracy: ±0.5%
■ Current range: 0..20mA
■ Max. load resistance: 500 Ohm
Peripheral Connections
■ Via front panel on a shielded 25-pin D-Sub
receptacle connector
■ Via carrier board (rear I/O)
M-Module Characteristics
■ A08, D16, INTA, IDENT
Electrical Specifications
■ Isolation voltage: 500V DC
■ Supply voltage/power consumption:
■■ With on-board DC/DC converter:
+5V (4.85V..5.25V), 850mA
typ., ±12V 300mA typ.
■■ Without DC/DC converter: 100mA typ.
■■ External supply ±15V: -100mA
(no load connected), +110mA
(no load connected)
■ MTBF: tbd.
Mechanical Specifications
■ Dimensions: conforming to
M-Module Standard
■ Weight: 98g
Environmental Specifications
■ Temperature range (operation):
■■ 0..+60°C
■■ Industrial temperature range on request
■■ Airflow: min. 10m
3
/h
■ Temperature range (storage): -40..+85°C
■ Relative humidity range (operation):
max. 95% non-condensing
■ Relative humidity range (storage):
max. 95% non-condensing
■ Altitude: -300m to + 3,000m
■ Shock: 15g/0.33ms, 6g/6ms
■ Vibration: 1g/5..2,000Hz
Safety
■ PCB manufactured with a flammability rating
of 94V-0 by UL recognized manufacturers
EMC
■ Tested according to EN 55022 / 1999-05
(radio disturbance) and EN 55024 / 1999-05
(immunity) with regard to CE conformity
Software Support
■ MEN Driver Interface System
(MDIS for Windows, Linux, VxWorks, QNX,
RTX, OS-9)