Product data

78
M-Module Mezzanine I/O
MEN M-Module Mezzanine I/O
M62 – 16 Analog Outputs
16 current or voltage outputs
(different versions)
12 bits resolution
15 µs acquisition/conversion time
Optical isolation
D/A Conversion
16 channels
12 bits
Conversion time 15µs
±2 LSB gain
Voltage Output
Output current: 2mA max.
Output linearity: ±1 LSB
Accuracy: ±0.2%, ±1 LSB differential
Voltage ranges: 0..10V; -10V..+10V
Current Output
Accuracy: ± 0.5%
Current range : 4..20mA
(other ranges possible on request)
Max. output voltage 6V
Max. load resistance 300 Ohm
Possible Configurations
16 voltage outputs
16 current outputs
8 voltage outputs
8 current outputs
Peripheral Connections
Via front panel on a shielded 25-pin D-Sub
receptacle connector
Via carrier board (rear I/O)
M-Module Characteristics
A08, D16, IDENT
Electrical Specifications
Isolation voltage: 500V DC
Supply voltage/power consumption:
+5V (4.85V..5.25V), 110mA typ.
(without DC/DC converter), 560mA
(with DC/DC, voltage outputs without load)
External supply ±15V: 04M062-01
(voltage output): +90mA typ., -25mA
without load; 04M062-02 (current output):
+129mA typ., -48mA without load
MTBF: 560,000h @ 50°C
Mechanical Specifications
Dimensions: conforming to
M-Module Standard
Weight: 100g
Environmental Specifications
Temperature range (operation):
0..+60°C
Industrial temperature range on request
Airflow: min. 10m
3
/h
Temperature range (storage): -40..+85°C
Relative humidity range (operation):
max. 95% non-condensing
Relative humidity range (storage):
max. 95% non-condensing
Altitude: -300m to + 3,000m
Shock: 15g/0.33ms, 6g/6ms
Vibration: 1g/5..2,000Hz
Safety
PCB manufactured with a flammability rating
of 94V-0 by UL recognized manufacturers
EMC
Tested according to EN 55022 / 1999-05
(radio disturbance) and EN 55024 / 1999-05
(immunity) with regard to CE conformity
Software Support
MEN Driver Interface System
(MDIS for Windows, Linux, VxWorks, QNX,
RTX, OS-9)