Product data
34
VMEbus
MEN VMEbus
VMEbus
■ Only one slot required on the VMEbus
■ A24, A16, D16, D08 (E/O) slave
■ D08(O) interrupter
M-Modules
■ B201S: one M-Module slot on the board
■ B202S: two M-Module slots on the board
■ M-Module characteristics: D08, D16, A08,
INTA, INTC
Peripheral Connections
■ Via front panel
Electrical Specifications
■ Supply voltage/power consumption:
■■ B201S: +5V (+5%, -0%), 350mA typ.
(without M-Modules)
■■ B202S: +5V (+5%, -0%), 320mA typ.
(without M-Modules)
■ MTBF: 52,000h @ 50°C
Mechanical Specifications
■ B201S:
■■ Dimensions: standard single Eurocard,
100mm x 160mm
■■ Front panel: aluminum with 1 handle,
cut-out for front connector of M-Module
■■ Weight: 108g
■ B202S:
■■ Dimensions: 110mm x 155mm
■■ Front panel: aluminum without handles,
cut-outs for front connectors of 2 M-Modules
■■ Weight: 102g (without M-Modules)
Environmental Specifications
■ Temperature range (operation):
■■ 0..+60°C or -40..+85°C
■■ Airflow: min. 10m
3
/h
■ Temperature range (storage): -40..+85°C
■ Relative humidity range (operation):
max. 95% non-condensing
■ Relative humidity range (storage):
max. 95% non-condensing
■ Altitude: -300m to + 3,000m
■ Shock: 15g/0.33ms, 6g/6ms
■ Vibration: 1g/5..2,000Hz
Safety
■ PCB manufactured with a flammability rating
of 94V-0 by UL recognized manufacturers
EMC
■ Tested according to EN 55022 / 1999-05
(radio disturbance) and EN 55024 / 1999-05
(immunity) with regard to CE conformity
Software Support
■ M-Module drivers for Windows, VxWorks,
Linux, OS-9, RTX as supported
■ 1 M-Module slot
■ 1 VMEbus slot
■ 2 M-Module slots
■ 1 VMEbus slot
B202S / B201S – 3U VMEbus Carrier Boards for M-Modules