Product data
CAN Controllers
■ I82527
■ Standard and extended frames
■ Up to 15 message objects
■ Up to 1Mbit/s
■ ISO 11898 high speed up to 1Mbit/s, both
channels optically isolated using DC/DC
converters
I/O Processors
■ MC68331, 32-bit CPU32, 24MHz
Memory
■ 1MB shared SRAM for communication and
program per channel
Physical Interface
■ ISO high speed coupling (optically isolated)
Peripheral Connections
■ Via front panel on a shielded 25-pin D-Sub
receptacle connector
■ Via carrier board (rear I/O)
M-Module Characteristics
■ A08, D16, INTA, IDENT
Electrical Specifications
■ Isolation voltage: 500V DC
■ Supply voltage/power consumption:
+5V (4.85V..5.25V), 470mA
max. (2 channels), 280mA (1 channel)
■ MTBF: 40,000h @ 50°C
Mechanical Specifications
■ Dimens.: conforming to M-Module Standard
■ Weight: 84g
Environmental Specifications
■ Temperature range (operation):
■■ 0..+60°C or -40..+85°C
■■ Airflow: min. 10m
3
/h
■ Temperature range (storage): -40..+85°C
■ Relative humidity range (oper.): max. 95% nc
■ Relative humidity range (stor.): max.95% nc
■ Altitude: -300m to + 3,000m
■ Shock: 15g/0.33ms, 6g/6ms
■ Vibration: 1g/5..2,000Hz
Software Support
■ CANopen firmware (Vector Informatik)
■ ICANL2 firmware and toolbox (MEN)
■ MEN Driver Interface System (MDIS for
Windows, Linux, VxWorks, QNX, RTX, OS-9)
110
M-Module Mezzanine I/O
MEN M-Module Mezzanine I/O
M79 – Profibus DP Slave Interface
■ DIN19245
■ Isolated RS485
■ Local 16-bit CPU
■ 12Mbits/s data transfer rate
■ Complete Softing Profibus software on board
■ Compatible with Softing tools
C165 CPU
■ 16-bit data bus, 20-bit address bus
■ Complete Profibus DP software on one
M-Module
■ Local interrupt controller
■ Hardware watchdog
Slave: SPC 3 Profibus Controller
■ Up to 12Mbaud data rate
■ 8-bit interface (local)
■ Complete DP slave protocol
Master: ASPC 2 Profibus Controller
■ Optional, for M79 as Profibus Master
■ Up to 12Mbaud data rate
■ 16-bit DMA interface (local)
■ Complete bus access protocol
■ Up to 127 active or passive stations
Miscellaneous
■ 1MB shared memory for communication
and program
■ Isolated RS485 Profibus interface
Peripheral Connections
■ Via front panel on a shielded 9-pin D-Sub
receptacle connector
M-Module Characteristics
■ A08, D16, INTA, IDENT
Electrical Specifications
■ Electrical isolation: 500V DC
■■ 500V DC between isolated and digital side
■■ Voltage between the connector shield and
isolated ground is limited to 180V using a
varistor; AC coupling between connector
shield and isolated ground through 47nF
capacitor
■ Supply voltage/power consumption:
■■ +5V (4.85V..5.25V), 287mA
■ MTBF: 430,000h @ 50°C
Mechanical Specifications
■ Dimensions: conforming to
M-Module Standard
■ Weight: 53g
Software Support
■ Softing protocol portation
(ISO/OSI protocol layer 2/DP)
■ MEN Driver Interface System
(MDIS for Windows, Linux, VxWorks, QNX,
RTX, OS-9)
■ Full CAN/Extended CAN
■ Two independent channels
■ Two local 32-bit CPUs
■ ISO high-speed coupling
■ 1Mbit/s data transfer rate
■ Optical isolation
■ CANopen master and slave software support (Vector Informatik)
■ Intelligent CAN Layer 2 support
M79 M65
M65 – Intelligent Dual CAN Interface