Product data

106
M-Module Mezzanine I/O
MEN M-Module Mezzanine I/O
M50 – Synchro/Resolver Converter
Resolver/synchro-to-digital converter
Up to 16 bits resolution
On-board reference frequency generation
On-board signal conditioning
2 arc minutes accuracy
Analog velocity output
Optical isolation
AD2S82A Resolver-to-Digital
Converter
Resolution: 10/12/14/16 bits
Reference input voltage:
variable, 2V RMS..90V RMS/115V
RMS
Reference output voltage:
max. 21V RMS, 1.5W
Reference frequency range: 50..20,000Hz
Accuracy:
±2/±4/±8/±22 arc min, ±1LSB
(resolver input)
Accuracy: ±9/±13/±15/±29 arc min,
±1LSB (synchro input)
Tracking rate: depends on frequency
and resolution (max. 1040 rps)
Small/large step settling time: depends on
frequency and resolution
Miscellaneous
Input signals: 10% max. harmonic distortion
Velocity output: ±8V
Peripheral Connections
Via front panel on a shielded 25-pin D-Sub
receptacle connector
Via carrier board (rear I/O)
M-Module Characteristics
A08, D16, INTA, IDENT
Electrical Specifications
Isolation voltage: 500V DC
Supply voltage/power consumption:
+5V (4.85V..5.25V), 550mA typ.
MTBF: 34,000h @ 50°C
Mechanical Specifications
Dimensions: conforming to
M-Module Standard
Weight: 102g
Environmental Specifications
Temperature range (operation):
0..+60°C
Industrial temperature range on request
Airflow: min. 10m
3
/h
Temperature range (storage): -40..+85°C
Relative humidity range (operation):
max. 95% non-condensing
Relative humidity range (storage):
max. 95% non-condensing
Altitude: -300m to + 3,000m
Shock: 15g/0.33ms, 6g/6ms
Vibration: 1g/5..2,000Hz
Safety
PCB manufactured with a flammability rating
of 94V-0 by UL recognized manufacturers
EMC
Tested according to EN 55022 / 1999-05
(radio disturbance) and EN 55024 / 1999-05
(immunity) with regard to CE conformity
Software Support
MEN Driver Interface System
(MDIS for Windows, Linux, VxWorks, QNX,
RTX, OS-9)