Product data

101
M-Module Mezzanine I/O
MEN M-Module Mezzanine I/O
A/D Conversion
12 bits/35µs
Simultaneous sampling of four channels
Precision:
Offset < 5mV
Gain < 0.2%
Sampling frequency: max. 28kHz
Input Conditioning
Precision: ±0.1%
Input resistance > 100 kOhm
Voltage Input
4 analog inputs, differential
±1.25V, ±2.5V, ±5V, ±10V, ±20V
Common mode rejection: 55dB
Programmable Low-Pass Filter
Operation range: 5Hz..10,000Hz
Filter transconductance: 48dB/octave
FIFO
512 bytes, 64 samples (4 words each)
Peripheral Connections
Via front panel on a shielded 25-pin D-Sub
receptacle connector
Via carrier board (rear I/O)
M-Module Characteristics
A08, D16, INTA, DMA, IDENT, TRIGI
Electrical Specifications
Isolation voltage
500V DC between M-Module interface and
analog input connector
Voltage between the connector shield and
analog input connector is limited to 180V
using a varistor; AC coupling between
connector shield and analog input
connector through 47nF capacitor
Supply voltage/power consumption:
Digital part: +5V (4.85V..5.25V),
220mA max.
Analog part: ±15V (±5%), +200mA,
-100mA typ.
MTBF: 228,000h @ 50°C
Mechanical Specifications
Dimensions: conforming to
M-Module Standard
Weight: 75g
Environmental Specifications
Temperature range (operation):
0..+60°C or -40..+85°C
Airflow: min. 10m
3
/h
Temperature range (storage): -40..+85°C
Relative humidity range (operation):
max. 95% without condensation
Relative humidity range (storage):
max. 95% without condensation
Altitude: -300m to + 3,000m
Shock: 15g/0.33ms, 6g/6ms
Vibration: 1g/5..2,000Hz
Safety
PCB manufactured with a flammability rating
of 94V-0 by UL recognized manufacturers
EMC
Tested according to EN 55022 / 1999-05
(radio disturbance) and EN 55024 / 1999-05
(immunity) with regard to CE conformity
Software Support
MEN Driver Interface System
(MDIS for Windows, Linux, VxWorks, QNX,
RTX, OS-9)
M16 – Quad Input Analog Data Acquisition
4 differential DC/AC voltage input channels
12 bits resolution
35µs acquisition
±1.25V, ±2.5V, ±5V, ±10V, ±20V measuring ranges
Simultaneous sampling of all channels
External measurement trigger
FIFO for data buffering
Optical isolation