User`s guide
Connecting to other DTE and DCE Equipment
For DCE and DTE equipment that require DCD and DSR be connected for proper
operation, the following interface can be used. Note that the supplied serial cable does
not provide the connections shown in the following diagrams.
2
3
5
7
8
6
4
1
2
3
5
7
8
6
4
1
Receive Data
Transmit Data
Signal Ground
Request To Send
Clear To Send
Data Set Read
y
Data Terminal Read
y
Data Carrier Detec
t
DTE Host
D9
Radio Modem
D9F
RMX232 to DTE host interface
2
3
5
7
8
6
4
1
2
3
5
7
8
6
4
1
Receive Data
Transmit Data
Signal Ground
Request To Send
Clear To Send
Data Set Ready
Data Terminal Ready
Data Carrier Detect
DCE Host
D9
Radio Modem
D9F
RMX232 to DCE host interface
User’s Guide Connecting the Radio Modem 5-4